Related Experiment Video
Updated: Jan 31, 2026

Impact Assessment of Repeated Exposure of Organotypic 3D Bronchial and Nasal Tissue Culture Models to Whole Cigarette Smoke
Published on: February 12, 2015
Development of a quantitative method for assessment of dose in in vitro evaluations using a VITROCELL® VC10® smoke
Brian M Keyser1, Robert Leverette1, Kathy Fowler1
1RAI Services Company(1), Scientific & Regulatory Affairs, 401 North Main Street, Winston-Salem, NC 27101, USA.
Abstract:
The assessment of potential cytotoxicity or genotoxicity of combustible tobacco products has historically been performed using partitioned exposures (i.e. total particulate matter [TPM], gas vapor phase [GVP]) rather than whole smoke. The VITROCELL® VC10® smoke exposure system offers multiple platforms for air liquid interface (ALI) or air agar interface (AAI) exposure to mimic in vivo-like conditions for assessing the toxicological impact of whole smoke using in vitro assays (e.g. cytotoxicity, mutagenicity and DNA modifications). The aims of this study were to investigate dosimetry during whole smoke exposure in the VITROCELL® VC10® smoking robot using quartz crystal microbalances (QCMs) and to support the use of photometers for concurrent assessment of 'dose' during whole smoke exposures. QCM results showed consistent deposition across different exposure chambers, between dilution bars, experiments and modules. Higher levels of variation were noted at higher airflows (i.e., >8 L/min). Dosimetry assessed using photometers also showed a high level of consistency between experiments, with no notable impact on deposition on the QCM when the photometers were placed 'in-line' between the dilution bar and the exposure module. However, the use of photometers alone may be not be sufficient to estimate deposition; the predictability of the data-generated equation was poor. Further development of dosimetry methodology and information for use in validated in vitro biological test methods is needed to facilitate on-going aerosol-based research and relative assessment.
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Development of Analytical Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
In Vitro Drug Release Testing: Overview, Development and Validation
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...

