Related Experiment Video
Updated: Jan 31, 2026

Normothermic Ex Vivo Pancreas Perfusion for the Preservation of Pancreas Allografts before Transplantation
Published on: July 27, 2022
Hyaluronic Acid Is a Biomarker for Allograft Dysfunction and Predicts 1-Year Graft Loss After Liver Transplantation
A A Rostved1, S R Ostrowski2, L Peters3
1Department of Surgical Gastroenterology and Transplantation, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Background:
Allograft dysfunction after liver transplantation has a profound impact on the risks of death and retransplantation within the first year. We tested whether elevated hyaluronic acid (HA; a glycosaminoglycan cleared by hepatic sinusoidal endothelium) levels may predict excess risk of graft loss.
Methods:
This was a retrospective single-center prognostic cohort study. Patients with either a plasma sample before transplantation, an early post-transplantation sample nearest day 30 (range 10-89 d, 80% within days 15-60), or both were included. Plasma HA was measured with the use of enzyme-linked immunosorbent assays. The primary end point was 1-year graft loss (all-cause mortality and retransplantation). A secondary end point was biliary stricture.
Results:
In this study, 169 of 196 patients who received a liver transplant in the study period were included. Pre-transplantation HA (n = 152) did not predict graft loss. Post-transplantation HA (n = 124) was higher among patients with graft loss (median, 177 μg/L [interquartile range (IQR), 89-465] vs 54 μg/L [IQR 37-93]) and was a strong predictor of this outcome (hazard ratio per 50 μg/L, 1.24 [95% confidence interval [CI], 1.14-1.34]). The discriminatory ability of HA was high (area under the receiver operating characteristic curve, 0.86 [95% CI, 0.77-0.94]) and noninferior to other liver function tests. When adjusted for known risk factors of graft loss, HA remained an independent predictor of graft loss.
Conclusions:
High post-transplantation plasma HA level was a strong predictor of 1-year all-cause mortality and retransplantation, whereas pre-transplantation levels were not, despite variety in the time span of blood sampling. Prospective studies are warranted to assess the utility of HA in liver transplantation.
Related Concept Videos
Predicting Products: SN1 vs. SN2
With increased substitution on the alkyl halide,...
Acidity of 1-Alkynes
The acidic strength of hydrocarbons follows the order: Alkynes > Alkenes > Alkanes. The strength of an acid is commonly expressed in units of pKa — the lower the pKa, the stronger the acid. Among the hydrocarbons, terminal alkynes have lower pKa values and are, therefore, more acidic. For example, the pKa values for ethane, ethene, and acetylene are 51, 44, and 25, respectively, as shown here.
Loss of Carboxy Group as CO2: Decarboxylation of Malonic Acid Derivatives
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Predicting Molecular Geometry
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...

