Hyaluronic Acid Is a Biomarker for Allograft Dysfunction and Predicts 1-Year Graft Loss After Liver Transplantation

A A Rostved1, S R Ostrowski2, L Peters3

  • 1Department of Surgical Gastroenterology and Transplantation, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.

Transplantation Proceedings
|December 23, 2018
PubMed
Abstract

Related Concept Videos

Predicting Products: SN1 vs. SN202:27

Predicting Products: SN1 vs. SN2

Nucleophilic substitution reactions of alkyl halides can proceed via an SN1 or an SN2 mechanism. While in SN2 reactions, the nucleophile attacks the substrate simultaneously as the leaving group departs, in SN1 reactions, the substrate first dissociates to give the carbocation intermediate. Various factors such as the structure of the substrate, the strength of the nucleophile, and the nature of the solvent promote one mechanism over the other.
With increased substitution on the alkyl halide,...
17.3K
Acidity of 1-Alkynes02:42

Acidity of 1-Alkynes


The acidic strength of hydrocarbons follows the order: Alkynes > Alkenes > Alkanes. The strength of an acid is commonly expressed in units of pKa — the lower the pKa, the stronger the acid. Among the hydrocarbons, terminal alkynes have lower pKa values and are, therefore, more acidic. For example, the pKa values for ethane, ethene, and acetylene are 51, 44, and 25, respectively, as shown here.
11.2K
Loss of Carboxy Group as CO2: Decarboxylation of Malonic Acid Derivatives01:35

Loss of Carboxy Group as CO2: Decarboxylation of Malonic Acid Derivatives

Just like β-keto acids—which upon thermal decarboxylation form ketones—β-dicarboxylic acids undergo decarboxylation to generate monocarboxylic acids with the liberation of carbon dioxide.
2.6K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
541
Predicting Molecular Geometry02:27

Predicting Molecular Geometry

VSEPR Theory for Determination of Electron Pair Geometries
45.8K
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
389