Objectives:
The aim of this in vitro study was to compare the heat generation during guided osteotomy preparation (GOP) with that of a conventional approach (CA) for a single and sequential drilling protocol.
Methods:
Temperature measurements were performed during standardized osteotomy preparations in polyurethane foam blocks with an infrared camera. The four groups included single and sequential drilling with and without the use of a surgical guide. In the first group (single CA) and the second group (single GOP), only the final drills diameters were applied once. In the third group (sequential CA) and the fourth group (sequential GOP), two to four drills with increasing diameters were applied. Guided and conventional as well as single and sequential drilling were compared using a one-way ANOVA with Tukey post hoc test. The level of statistical significance was set at α = 0.05.
Results:
Guided osteotomy preparation showed statistically significant higher temperatures than CA for the 2.2 mm, the 3.5 mm, and the 4.2 mm drill (p = 0.032, p = 0.005 and p < 0.001, respectively). Sequential drilling led to higher heat generation and longer duration of latent heat than single drilling. For all drilling procedures, the duration of heat exposure over critical temperature was less than 1 min, except for the sequential GOP drilling protocol with the 4.2 mm drill (76 s).
Conclusions:
Guided drilling requires specific attention to heat development. When guided implant surgery is performed, a single drilling procedure could alleviate heat production compared to a sequential procedure.
Related Concept Videos
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Quantifying Heat
Heat Flow and Specific Heat
Enolate Mechanism Conventions