Related Experiment Video
Updated: Jan 31, 2026

Hyperpolarized Xenon for NMR and MRI Applications
Published on: September 6, 2012
Rapid single-breath hyperpolarized noble gas MRI-based biomarkers of airspace enlargement
Andrew Westcott1,2, Fumin Guo1,3, Grace Parraga1,2
1Robarts Research Institute, University of Western Ontario, London, Canada.
Background:
Multi-b diffusion-weighted hyperpolarized-gas MRI measures pulmonary airspace-enlargement using apparent diffusion coefficients (ADCs) and mean-linear-intercepts (Lm ).
Purpose:
To develop single-breath 3D multi-b diffusion-weighted 3 He and 129 Xe MRI using k-space undersampling. Rapid, cost-efficient, single-breath acquisitions may facilitate clinical translation.
Study Type:
Prospective.
Subjects:
We evaluated 12 participants, including nine subjects (mean age = 69 ± 9) who were included in the retrospective experiment and three chronic pulmonary obstruction disease (COPD) patients (mean age = 81 ± 6) who participated in the prospective study.
Field Strength:
A whole-body 3 T 2D/3D fast gradient recall echo (FGRE) sequence.
Assessment:
Hyperpolarized 3 He/129 Xe MRI, spirometry, plethysmography computed tomography (CT). We evaluated 129 Xe ADC/morphometry estimates by retrospectively undersampling previously acquired fully sampled multibreath, multi-b diffusion-weighted data. Next, we prospectively evaluated the feasibility of accelerated (AF = 7) 3 He MRI static-ventilation/T2 * (extra short-TE, b = 0 image) and ADC/morphometry (five b-values) maps using a single gas-dose and 16-second breath-hold. To conservatively evaluate cost-improvement, we compared total costs of single vs. multiple 129 Xe doses.
Statistical Tests:
Multivariate analysis of variance, independent t-tests and voxel-by-voxel basis difference test.
Results:
For the retrospectively undersampled 129 Xe data, a nonsignificant mean difference for ADC/Lm of 14%/12%, 12%/8%, and 11%/9% was observed (all, P > 0.4) between the fully sampled and accelerated data for the never-smoker, COPD, and alpha-1 antitrypsin deficiency (AATD) groups, respectively. The control never-smoker group had significantly lower ADC (P < 0.001) and Lm (P < 0.001) than the COPD/AATD group for both fully sampled and accelerated data. For the prospectively acquired 3 He MRI data, static-ventilation, T2 *, ADC, and morphometry maps were acquired using a single 16-second breath-hold scan and single gas dose. Accelerated imaging resulted in cost savings of ~$US 1000/patient, a conservative estimate based on 129 Xe MRI dose savings (single vs. five doses).
Data Conclusion:
This is a proof-of-concept demonstration of accelerated (7×) morphometry that shows that less cost- and time-efficient multibreath methods that lead to variability and patient fatigue may be avoided in the future.
Level Of Evidence:
2 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018.
Related Concept Videos
Noble Gases
The elements in group 18 are noble gases (helium, neon, argon, krypton, xenon, and radon). They earned the name “noble” because they were assumed to be nonreactive since they have filled valence shells. In 1962, Dr. Neil Bartlett at the University of British Columbia proved this assumption to be false.
Breathing
Enlargement of the Plasma Membrane
Gas Exchange and Transport
Kinetic Molecular Theory and Gas Laws Explain Properties of Gas Molecules
Gas Laws: Boyle's, Gay-Lussac, Charles', Avogadro's, and Ideal Gas Law