Foramen ovale blood flow and cardiac function after main pulmonary artery occlusion in fetal sheep
Juulia Lantto1, Tiina Erkinaro2, Mervi Haapsamo3
1Department of Obstetrics and Gynecology, Oulu University Hospital and University of Oulu, Oulu, Finland.
New Findings:
What is the central question of this study? At near-term gestation, foramen ovale blood flow accounts for a significant proportion of fetal left ventricular output. Can the foramen ovale increase its volume blood flow when right ventricular afterload is increased by main pulmonary artery occlusion? What is the main finding and its importance? Foramen ovale volume blood flow increased during main pulmonary artery occlusion. However, this increase was attributable to an increase in fetal heart rate, because left ventricular stroke volume remained unchanged. These findings suggest that the foramen ovale has a limited capacity to increase its volume blood flow.
Abstract:
The foramen ovale (FO) accounts for the majority of fetal left ventricular (LV) output. Increased right ventricular afterload can cause a redistribution of combined cardiac output between the ventricles. To understand the capability of the FO to increase its volume blood flow and thus LV output, we mechanically occluded the main pulmonary artery in seven chronically instrumented near-term sheep fetuses. We hypothesized that FO volume blood flow and LV output would increase during main pulmonary artery occlusion. Fetal cardiac function and haemodynamics were assessed by pulsed and tissue Doppler at baseline, 15 and 60 min after occlusion of the main pulmonary artery and 15 min after occlusion was released. Fetal ascending aorta and central venous pressures and blood gas values were monitored. Main pulmonary artery occlusion initially increased fetal heart rate (P < 0.05) from [mean (SD)] 158 (7) to 188 (23) beats min-1 and LV cardiac output (P < 0.0001) from 629 (198) to 776 (283) ml min-1 . Combined cardiac output fell (P < 0.0001) from 1524 (341) to 720 (273) ml min-1 . During main pulmonary artery occlusion, FO volume blood flow increased (P < 0.001) from 507 (181) to 776 (283) ml min-1 . This increase was related to fetal tachycardia, because LV stroke volume did not change. Fetal ascending aortic blood pressure remained stable. Central venous pressure was higher (P < 0.05) during the occlusion than after it was released. During the occlusion, fetal pH decreased and increased. Left ventricular systolic dysfunction developed while LV diastolic function was preserved. Right ventricular systolic and diastolic function deteriorated after the occlusion. In conclusion, the FO has a limited capacity to increase its volume blood flow at near-term gestation.
Related Concept Videos
Blood Flow
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Treatment for Pulmonary Arterial Hypertension: Phosphodiesterase Inhibitors
Among the PDE5 inhibitors, sildenafil (Revatio) stands out as a competitive and selective inhibitor. It operates by elevating cellular levels of cGMP and augmenting signaling through the cGMP-PKG pathway, promoting vasodilation. Upon oral...
Characteristics and Functions of Blood
The primary function of blood is to transport oxygen and carbon dioxide between tissues and the lungs. Oxygenated blood is bright red, while oxygen-depleted blood is darker. It also carries...
Cloning of Dolly the Sheep