Background:
Platelet concentrates (PCs) treated by the pathogen inactivation technology (PI) using amotosalen and UVA illumination (PI-PCs) can be manufactured in additive solutions (PAS-III and PAS-IIIM) or in 100% Plasma. Quality control (QC) is an integral part of the production. We capitalized on our ongoing QC program to capture 8 years-worth of data on parameters related to the quality of 116,214 PI-PCs produced under different manufacturing methods.
Materials And Methods:
Selected in vitro parameters of metabolism, activation, and storage were analyzed for the different manufacturing periods to compare PI-PCs versus conventional PCs (C-PCs) resuspended in different PAS.
Results And Discussion:
All BC-PCs met quality standards for pH and dose and residual leucocytes. As expected, storage time correlated with increased lactate, LDH, Annexin V, CD62, sCD40 L levels and decreased glucose and pH. With PAS-IIIM, higher levels of glucose were observed toward the end of shelf life (p < 0.0001) with lower platelet activation markers Annexin V (p = 0.038) and CD62 (p = 0.0006). Following PI implementation, a low expire rate of <0.5% was observed. While a 2.3% mean increase in the production of PCs occurred from 2011 to 2015, the distribution of red blood cell concentrates dropped by 4.4%. A mean incidence of 0.14% for transfusion-related adverse reaction was observed while PI-PCs were distributed, similar to the one observed with C-PCs. Overall, PI-PCs prepared in additive solutions consistently met quality standards. Those prepared in PAS-IIIM appeared to have better retention of in vitro characteristics compared to PAS-III though all demonstrated functionality and clinical effectiveness.