Temporal stability and specificity of high bipolar electrogram entropy regions in sustained atrial fibrillation:
Dhani Dharmaprani1, Andrew D McGavigan2, Darius Chapman3
1College of Medicine and Public Health, Flinders University of South Australia, Adelaide, SA, Australia.
Background:
The potential utility of entropy (En) for atrial fibrillation (AF) mapping has been demonstrated in previous studies by multiple groups, where an association between high bipolar electrogram (EGM) entropy and the pivot of rotors has been shown. Though En is potentially attractive new approach to ablation, no studies have examined its temporal stability and specificity, which are critical to the application of entropy to clinical ablation. In the current study, we sought to objectively measure the temporal stability and specificity of bipolar EGM entropy in medium to long term recordings using three studies: i) a human basket catheter AF study, ii) a tachypaced sheep AF study and iii) a computer simulation study.
Objective:
To characterize the temporal dynamics and specificity of Approximate, Sample and Shannon entropy (ApEn/SampEn/ShEn) in human (H), sheep (S), and computer simulated AF.
Methods:
64-electrode basket bi-atria sustained AF recordings (H:15 min; S:40 min) were separated into 5 s segments. ShEn/ApEn/SampEn were computed, and co-registered with NavX 3D maps. Temporal stability was determined in terms of: (i) global pattern stability of En and (ii) the relative stability the top 10% of En regions. To provide mechanistic insights into underlying mechanisms, stability characteristics were compared to models depicting various propagation patterns. To verify these results, cross-validation was performed across multiple En algorithms, across species, and compared with dominant frequency (DF) temporal characteristics. The specificity of En was also determined by looking at the association of En to rotors and areas of wave cross propagation.
Results:
Episodes of AF were analysed (H:26 epochs, 6040 s; S:15 epochs, 14,160 s). The global pattern of En was temporally unstable (CV- H:13.42% ± 4.58%; S:14.13% ± 8.13%; Friedman- H: p > 0.001; S: p > 0.001). However, within this dynamic flux, the top 10% of ApEn/SampEn/ShEn regions were relatively temporally stable (Kappa >0.6) whilst the top 10% of DF regions were unstable (Kappa <0.06). In simulated AF scenarios, the experimental data were optimally reproduced in the context of an AF pattern with stable rotating waves surrounded by wavelet breakup (Kappa: 0.610; p < 0.0001).
Conclusion:
En shows global temporal instability, however within this dynamic flux, the top 10% regions exhibited relative temporal stability. This suggests that high En regions may be an appealing ablation target. Despite this, high En was associated with not just the pivot of rotors but also with areas of cross propagation, which suggests the need for future work before clinical application is possible.
Related Concept Videos
Entropy
Entropy
When an ideal gas expands isothermally, the disorder in the gas increases. From the molecular perspective, the gas molecules have more volume to move around in.
Consider an infinitesimal step in the expansion, which...
Sustainable Development
Standard Entropy Change for a Reaction
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
RNA Stability