Influence of Sternotomy on Delta Pulse Pressure and Delta Down During Open Chest Cardiac Surgery: A Preliminary Study
Eric Deflandre1, Simon Delande2, Jerome Cauvain2
1Department of Anesthesia, Clinique Saint-Luc de Bouge, Namur, Belgium; Department of Ambulatory Surgery, Clinique Saint-Luc de Bouge, Namur, Belgium; University of Liege, Liege, Belgium; Medical ASTES, Jambes, Belgium.
Objective:
Delta pulse pressure and delta down are used as dynamic preload indicators of fluid responsiveness during closed chest surgery. There are few data regarding their accuracy in open chest surgery. The present study aimed to evaluate the influence of sternotomy on the accuracy of both delta pulse pressure and delta down.
Design:
Prospective study.
Setting:
Single institution, nonacademic hospital.
Participants:
The study comprised 127 adult patients scheduled for elective open chest cardiac surgery.
Interventions:
Delta pulse pressure and delta down were calculated for all patients before and 10 minutes after sternotomy.
Measurements And Main Results:
Statistical analyses were performed to assess the influence of sternotomy on the accuracy of delta down and delta pulse pressure. Mann-Whitney and Bland-Altman analyses demonstrated a significant influence of sternotomy on delta pulse pressure values but not on delta down values. Among patients who had a positive delta down and/or delta pulse pressure before sternotomy, sternotomy significantly modified the delta pulse pressure value (p = 0.02), but not the delta down value (p = 0.22). The kappa coefficient indicated a very good agreement between delta down before and after sternotomy (0.83) and a fair agreement between delta pulse pressure before and after sternotomy (0.4). The difference between kappa coefficients was highly significant (p < 0.001).
Conclusions:
Within the study population, sternotomy significantly influenced delta pulse pressure but not delta down. In this preliminary study, delta down appeared to be more accurate to evaluate fluid responsiveness during open chest surgery than did delta pulse pressure. Before promoting delta down in current practice, confirmation is needed on a larger scale.
Related Concept Videos
The Delta-to-Delta Circuit
The Y-to-Delta Circuit
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
The Delta-to-Y Circuit
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...