Under-the-Flap Crosslinking and LASIK in Early Ectasia with Hyperopic Refractive Error
Sylvain El-Khoury1,2, Youssef Abdelmassih1,2, Mazen Amro1,3
1Beirut Eye Specialist Hospital, P.O. Box 116-5311, Al-Mathaf Square, Beirut, Lebanon.
Purpose:
To present safety, efficacy, and early results of a new combinational treatment for early corneal ectasia with hyperopic refractive error aimed to reinstate emmetropia and stabilize cornea.
Method:
This is a retrospective case series. All surgeries were performed at the Beirut Eye Specialist Hospital, Lebanon. Surgical procedure consisted of (1) lifting flap (post-LASIK ectasia)/creation of corneal flap (keratoconus), (2) application of excimer laser ablation to correct refractive error, (3) loose repositioning of flap, (4) under-the-flap irrigation with riboflavin 0.1% dextran solution, and (5) application of UVA light.
Results:
A total of 7 eyes (4 patients; mean age 24.25 years; all male) were included. 2 patients had early keratoconus, and 2 patients had early post-LASIK ectasia. Pretreatment vs. last postoperative follow-up visit (mean 11.25 months; range 6-15 months) UDVA (logMAR), spherical equivalent (SE) (D), astigmatism (D), and central pachymetry (µm) were 0.35 ± 0.18 vs. 0.05 ± 0.07, p=0.017; -0.81 ± 0.67 vs. -0.46 ± 0.57, p=0.078; 2.46 ± 0.53 vs. 0.68 ± 0.28, p=0.018; and 547 ± 58 vs. 536 ± 49, p=0.07, respectively. In all eyes, BCVA was 0.1 logMAR or better before and after treatment. No eye showed a decrease in BCVA. Two eyes of one patient had an epithelial ingrowth, which was removed in one case. Follow-up results showed no major complications and no progression of corneal ectasia.
Conclusion:
Early results showed that under-the-flap CXL with excimer laser correction is an effective treatment for early hyperopic keratectasia, with the advantage of rapid recovery, postoperative corneal stability, and no epithelial healing complications. The procedure seems to bear a risk for postoperative epithelial growth into the flap interface.
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Random Error
Margin of Error
Standard Error of the Mean
The standard error of the mean is an example of a standard error. It is a unique standard deviation known as the standard deviation of the sampling distribution of the mean. The standard error of the mean is a statistic that calculates how correctly a sample distribution represents a...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...