High-risk human papillomavirus detection in oropharyngeal cancers: Comparison of saliva sampling methods
Kai Dun Tang1,2, Liz Kenny3,4,5, Ian H Frazer6
1The School of Biomedical Sciences, Institute of Health and Biomedical Innovation, Queensland University of Technology, Kelvin Grove, Queensland, Australia.
Background:
Accumulating evidence has suggested the utility of salivary oral rinse as a diagnostic fluid to detect oral human papillomavirus (HPV) DNA, but there are many methods for collecting saliva.
Methods:
Salivary oral rinse and unstimulated whole mouth saliva samples were collected from 45 oropharyngeal cancer (OPC) patients.
Results:
We show a positive correlation of HPV-16 E2 (r = 0.95, P < 0.0001) and E6/7 (r = 0.93, P < 0.0001) relative copy number as well as HPV genotypes in both sample methods. There was a significant correlation between the two sample methods in the ratio of HPV16 E2 to E6/7 DNA (r = 0.46, P < 0.01). Consistent with previous studies, a mixed HPV-16 form (episomal and integrated) was commonly found in both saliva and tumor samples.
Conclusion:
Detection of HPV in saliva samples collected by either method yielded comparable results, and showed good sensitivity for detection of HPV derived from OPC.
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Salivary Glands and Saliva
Convenience Sampling Method
Convenience sampling is a non-random method of sample selection; this method selects individuals that are easily accessible and may result in biased data. For example, a marketing...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Sampling Methods: Overview
In analytical chemistry, the choice of...