Related Experiment Video
Updated: Jan 31, 2026

A Novel Application of Musculoskeletal Ultrasound Imaging
Published on: September 17, 2013
MusIC method enhancement by a sensitivity study of its performance: Application to a lower limbs musculoskeletal
A Muller1, C Pontonnier1, G Dumont1
1a Univ Rennes, CNRS, Inria, IRISA - UMR 6074 , Rennes , France.
Abstract:
Providing a biomechanical feedback during experimental sessions is a real outcome for rehabilitation, ergonomics or training applications. However, such applications imply a fast computation of the biomechanical quantities to be observed. The MusIC method has been designed to solve quickly the muscle forces estimation problem, thanks to a database interpolation. The current paper aims at enhancing its performance. Without generating any database, the method allows to identify optimal densities (number of samples contained in the database) with respect to the method accuracy and the off-line computation time needed to generate the database. On a lower limbs model (12 degrees of freedom, 82 muscles), thanks to this work, the MusIC method exhibits an accuracy error of 0.1% with an off-line computation time lower than 10 minutes. The on-line computation frequency (number of samples computed per second) is about 58 Hz. Thanks to these improvements, the MusIC method can be used to produce a feedback during an experimentation with a wide variety of musculoskeletal models or cost functions (used to share forces into muscles). The interaction between the subject, the experimenter (e.g. trainer, ergonomist or clinician) and the biomechanical data (e.g. muscle forces) in experimental sessions is a promising way to enhance rehabilitation, training or design techniques.
Related Concept Videos
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Urine Studies II: Urine Culture and Sensitivity Test
Arteries of Lower Limbs
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the...
Self-Evaluation: Self-Enhancement and Self-Verification
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...

