Related Experiment Video
Updated: Jan 31, 2026

A Modified Technique for Transverse Aortic Constriction in Mice
Published on: August 18, 2022
Loop Transverse Colostomy - A Modified Technique
Cheng Cai1, Zhihui Dai1, Zhifeng Zhong1
1Department of Colorectal and Anal Surgery, Jinhua Municipal Central Hospital, Zhejiang University, Jinhua 321000, China.
Background:
Transverse colostomy is commonly performed to create temporary stoma in rectal cancer patients after neoadjuvant chemoradiotherapy. Conventional methods are either difficult to implement or to care for. To resolve these problems, we herein describe a modified transverse colostomy method.
Material And Methods:
Two sutures of peritoneum were made as "bridges" to support the stoma. Absorbable sutures were utilized to reinforce the stoma. Once the stoma was created, the stoma bag was immediately placed on the skin. 120 patients who received conventional or modified transverse colostomy between 2008 and 2014 were selected. Then, the two groups of patients were compared for stoma-related complications.
Results:
The operation time of stoma construction was 34±10 minutes for the conventional method and 28±7 minutes for the modified method (P= 0.009). There were no significant differences between the two groups with respect to postoperative bleeding, bowel obstruction or stoma retraction. Patients with conventional transverse colostomy were remarkably more likely to experience parastoma hernia (P= 0.048) and stoma prolapse (P= 0.038).
Conclusion:
In comparison with conventional methods, the modified transverse colostomy is a safe and effective diverting technique. It can be readily performed by all kinds of surgeons, especially those in underdeveloped areas. The technique represents a preferred method for constructing temporary stoma in rectal cancer patients treated with neoadjuvant chemoradiotherapy.
Related Concept Videos
Speed of a Transverse Wave
One of the key properties of any wave is the wave speed. Light...
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Feedback Loops
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Positive and Negative Feedback Loops