Related Experiment Video
Updated: Jan 31, 2026

Measuring Connectivity in the Primary Visual Pathway in Human Albinism Using Diffusion Tensor Imaging and Tractography
Published on: August 11, 2016
Diffusion tensor tractography to visualize axonal outgrowth and regeneration in a 4-cm reverse autograft sciatic
Angel F Farinas1, Alonda C Pollins1, Michael Stephanides2
1a Department of Plastic Surgery , Vanderbilt University Medical Center , Nashville , TN , USA.
Background:
Diffusion tensor tractography (DTT) has recently been shown to accurately detect nerve injury and regeneration. This study assesses whether 7-tesla (7T) DTT imaging is a viable modality to observe axonal outgrowth in a 4 cm rabbit sciatic nerve injury model fixed by a reverse autograft (RA) surgical technique.
Methods:
Transection injury of unilateral sciatic nerve (4 cm long) was performed in 25 rabbits and repaired using a RA surgical technique. Analysis of the nerve autograft was performed at 3, 6, and 11 weeks postoperatively and compared to normal contralateral sciatic nerve, used as control group. High-resolution DTT from ex vivo sciatic nerves were obtained using 3D diffusion-weighted spin-echo acquisitions at 7-T. Total axons and motor and sensory axons were counted at defined lengths along the graft.
Results:
At 11 weeks, histologically, the total axon count of the RA group was equivalent to the contralateral uninjured nerve control group. Similarly, by qualitative DTT visualization, the 11-week RA group showed increased fiber tracts compared to the 3 and 6 weeks counterparts. Upon immunohistochemical evaluation, 11-week motor axon counts did not significantly differ between RA and control; but significantly decreased sensory axon counts remained. Nerves explanted at 3 weeks and 6 weeks showed decreased motor and sensory axon counts.
Discussion:
7-T DTT is an effective imaging modality that may be used qualitatively to visualize axonal outgrowth and regeneration. This has implications for the development of technology that non-invasively monitors peripheral nerve regeneration in a variety of clinical settings.
Related Concept Videos
Inertia Tensor
The diagonal components of the inertia tensor matrix represent the moments of inertia concerning the principal axes of the object. These primary axes are defined as the axes where the object experiences the least...
Diffusion
Diffusion
Modeling of Diode Reverse Characteristics
When a reverse voltage applied to a Zener diode exceeds its breakdown voltage, the diode enters the breakdown region. At this point, the...
Theories of Dissolution: Diffusion Layer Model
This process starts with a thin layer, saturated with the drug, forming at the interface between the solid and liquid. The solute then diffuses from this layer into the main solution. The Noyes-Whitney equation suggests that the rate of dissolution relies on the diffusion...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

