Related Experiment Video
Updated: Jan 31, 2026

Enhanced Genetic Analysis of Single Human Bioparticles Recovered by Simplified Micromanipulation from Forensic ‘Touch DNA’ Evidence
Published on: March 9, 2015
Toxicological Analysis of Insects on the Corpse: A Valuable Source of Information in Forensic Investigations
Mojtaba Salimi1, Yavar Rassi1, Omid Chatrabgoun2
1Department of Medical Entomology and Vector Control, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Background:
Entomotoxicology as a subset of forensic entomology can be used by analysis of carcass feeding insects to detecting of drugs or toxins, as well as the cause and manner of death in cases of ante-mortem drugs intoxication. Morphine is one of the deacetylate metabolites of heroin. The aim of this study was to determine the presence and quantity of morphine in insects on the carcass and compare them with decomposing carcass.
Methods:
Field of this study was in Chalabeh District and toxicological tests were carried out at the Department of Forensic Toxicology, Legal Medicine Center, Kermanshah, Iran in 2017. Morphine was inoculated into live rabbit as experimental model at concentrations of 12.5, 25, 50mg/ml, similar to those normally encountered in human overdoses, then quality and quantity of morphine were determined in insects such as Chrysomya albiceps (as the first wave of insect succession on human cadavers) fed on carcass.
Results:
Quantitative assessment at larvae showed that morphine was detected in all larvae (feeding and post feeding stage) fed on tissues from carcasses administered morphine, except for post-feeding larvae from R1 which received 12.5mg/ml dosage of morphine.
Conclusion:
Necrophagous insects are an indicator on the scene of crime and a potential source of information about the antemortem situation. Detection of drug in insects which is actually a reflection of the cause of death is possible.
Related Concept Videos
Osmoregulation in Insects
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
AC Sources
Sources of Law
Constitutional law is foundational, deriving from federal and state constitutions, and...

