Related Experiment Video
Updated: Jan 31, 2026

Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
Published on: February 17, 2023
Unattended versus attended automated office blood pressure: Systematic review and meta-analysis of studies using the
Anastasios Kollias1, Emelina Stambolliu1, Konstantinos G Kyriakoulis1
1Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
Abstract:
There is increasing interest in unattended automated office blood pressure (OBP) measurement, which gives lower blood pressure values than the conventional auscultatory OBP. Whether unattended automated OBP differs from standardized attended automated OBP performed using the same device and measurement protocol remains uncertain. A systematic review and meta-analysis of studies (aggregate data) comparing unattended vs attended automated OBP using the same device and measurement protocol (conditions, number of measurements, visits) was performed. Ten eligible studies (n = 1004, weighted age 60.8 ± 4.2 [SD] years, 55% males) were analyzed. Unattended OBP (pooled systolic/diastolic 133.9 [95% CI: 129.7, 138]/80.6 [95% CI: 77, 84.2] mm Hg) did not differ from attended OBP (135.3 [95% CI: 130.9, 139.6]/81 [95% CI: 77.6, 84.3] mm Hg); pooled systolic OBP difference -1.3, 95% CI: -4.3, 1.7 mm Hg and diastolic -0.4, 95% CI: -1.2, 0.3 mm Hg. Nine of ten studies achieved high quality score and no publication bias was identified. Meta-regression analysis did not reveal any effect of age, gender, or attended systolic OBP on the unattended-attended systolic OBP difference (P = NS for all). However, there was a trend toward higher attended than unattended OBP at higher OBP levels. These data suggest that, when the same device and measurement protocol are used, attended automated OBP provides similar blood pressure values as unattended automated OBP. Although unattended automated OBP is theoretically advantageous as it ensures that standardized conditions and measurement protocol are used, attended automated OBP, if carefully performed, appears to be a reasonable and practical alternative.
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Systematic Sampling Method
Systematic sampling is one of the simplest methods...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)

