Gate-Controlled Metal-Insulator Transition in TiS3 Nanowire Field-Effect Transistors

Michael Randle1, Alexey Lipatov2, Avinash Kumar1

  • 1Department of Electrical Engineering , University at Buffalo, The State University of New York , Buffalo , New York 14260-1900 , United States.

ACS Nano
|December 27, 2018
PubMed

Related Concept Videos

Properties of Transition Metals02:58

Properties of Transition Metals

Transition metals are defined as those elements that have partially filled d orbitals. As shown in Figure 1, the d-block elements in groups 3–12 are transition elements. The f-block elements, also called inner transition metals (the lanthanides and actinides), also meet this criterion because the d orbital is partially occupied before the f orbitals.
29.8K
Field Effect Transistor01:29

Field Effect Transistor

Field-effect transistors (FETs) are integral to electronic circuits and distinguished by their three-terminal setup: the gate, drain, and source. These transistors operate as unipolar devices, which utilize either electrons or holes as charge carriers, in contrast to bipolar transistors, which use both types of carriers. The primary function of the FET is to modulate the flow of these carriers from the source to the drain through a channel. The voltage difference between the gate and source...
1.2K
Conductors and Insulators01:19

Conductors and Insulators

Some materials may easily let electrical charges pass through them, while others obstruct their flow. The former are called conductors and the latter insulators. The atomic structures of materials determine whether they are conductors or insulators of electricity.
Most metals are conductors. Their atomic configuration is such that one or more electron(s) are loosely bound to the nucleus in each atom. Thus, a sea of mobile electrons are available in them, known as free electrons. Their easy...
10.8K
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
571
Phase Transitions02:31

Phase Transitions

Whether solid, liquid, or gas, a substance's state depends on the order and arrangement of its particles (atoms, molecules, or ions). Particles in the solid pack closely together, generally in a pattern. The particles vibrate about their fixed positions but do not move or squeeze past their neighbors. In liquids, although the particles are closely spaced, they are randomly arranged. The position of the particles are not fixed—that is, they are free to move past their neighbors to...
23.2K
Thermal Insulation in Masonry Walls01:22

Thermal Insulation in Masonry Walls

In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
547