Study Design:
Retrospective reliability study.
Objectives:
To investigate the intra- and interrater reliability of Cobb angle measurements on the plane of maximum curvature (PMC) using ultrasound (US) images on children with adolescent idiopathic scoliosis (AIS).
Summary Of Background Data:
Cobb angle measurement on posteroanterior (PA) radiographs is the gold standard to assess curve severity. However, the PA Cobb angle does not reflect the true three-dimensional deformity.
Methods:
One hundred one children with AIS (87 F; 14 M) (age: 13.7 ± 1.7 years) were recruited and 157 curves were recorded by clinicians on radiographs. Three raters, R1, R2, and R3 with 0, 4, and 20+ years of experience, respectively, measured the PA Cobb, vertebral axial rotation (VAR), PMC Cobb, and PMC orientations on US images. The true PMC orientations were determined using 3D reconstructions on the PA and lateral EOS radiographs. The reliability of R1 measurements on PMC orientations were validated using intermethod (US vs. EOS measurements) with the intraclass correlation coefficients (ICCs). Inter- and intrarater reliabilities, standard error measurements, and Bland-Altman's bias were used to report the PMC Cobb and VAR measurements.
Results:
Intermethod, inter-, and intrarater ICC(2,1) values for all reliability assessments were greater than 0.9. The mean absolute differences and the standard error measurements for both PMC Cobb and VAR were less than 4° and 0.5°, respectively. The PMC orientation was strongly correlated (r2 = 0.88) between both measurement modalities. There appeared to be a positive association between the difference of PMC and PA Cobb when the PA Cobb and the maximum VAR were greater than 30° and 14°, respectively.
Conclusion:
The PMC Cobb and VAR can be measured reliably on US images. Future studies should validate the PMC Cobb angle and to include a wider Cobb angle range on participants.
More Related Videos
09:57Obtaining Quality Extended Field-of-View Ultrasound Images of Skeletal Muscle to Measure Muscle Fascicle Length
Published on: December 14, 2020
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Related Concept Videos
Degree of Curvature and Radius of Curvature
Reliability and Validity
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
Vertebral Column: Regions and Curvature
Regions of the Vertebral Column
In an adult, the spine is subdivided into five regions: the cervical, the thoracic, the lumbar, the sacral, and the coccygeal region. The spine initially develops as a series of 33 vertebrae; after 20 years of age, the nine bones in the sacral region, five sacral, and four coccygeal bones fuse to form...
Maximum Power Transfer
By substituting the entire circuit with...
Maximum Size of Aggregate