Dispersion-guided ablation in conjunction with circumferential pulmonary vein isolation is superior to stepwise ablation approach for persistent atrial fibrillation
Related Experiment Video
Updated: Jan 31, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Rongjie Lin1, Cong Zeng1, Kai Xu1
1Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
Background:
Due to the lack of optimal ablation strategy, the success rate of persistent atrial fibrillation (AF) is still low. We hypothesize that a strategy that targeting pulmonary triggers and dispersion areas in atria improves prognosis of persistent AF.
Methods:
We prospectively enrolled 142 persistent AF patients admitted for catheter ablation. These patients were randomly assigned in a 1:1 ratio to ablation with circumferential pulmonary vein isolation (CPVI) + ablation of electrogram dispersion areas (71 patients, group A) or stepwise ablation strategy (71 patients, group B).
Results:
Procedural time and fluoroscopy time did not differ between group A and group B (204.6 ± 26.9 min vs 207.8 ± 26.3 min and 7.3 ± 1.3 min vs 7.1 ± 1.3 min, respectively, P > 0.05), however, radiofrequency delivery time in group A was significantly shorter than that in group B (70 ± 7.2 min vs 83.2 ± 9.1 min, P < 0.001). In total, 265 electrogram dispersion areas were identified in 67 patients, and the most prominent areas were roof, bottom, and inferoposterior wall. The rates of acute AF endpoint (including AF termination and AFCL elongation >30 ms) and termination in group A were significantly higher than that in group B (97.2% vs. 71.8% and 70.4% vs. 15.5%, respectively, P < 0.001). During a follow-up period of 204 ± 67 days, both AF-free and AF/AT-free survival in group A were significantly higher than that in group B (P = 0.012 and P = 0.014, respectively).
Conclusion:
Dispersion-guided ablation in conjunction with CPVI is efficient, personalized, and accurate for persistent AF.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Distribution and Dispersion
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Veins of Thorax
The azygos vein, positioned just right of the midline and anterior to the vertebral column, begins at the junction of the right ascending lumbar and subcostal veins, terminating in the superior vena cava. This vein drains blood from the right side of the thoracic wall, thoracic viscera, and posterior abdominal wall.
The...

