Related Experiment Video
Updated: Jan 31, 2026

A Semi-quantitative Approach to Assess Biofilm Formation Using Wrinkled Colony Development
Published on: June 7, 2012
Ischemic burden assessment of myocardial perfusion CT, compared with SPECT using semi-quantitative and quantitative
Osung Kwon1, Hye Jeon Hwang2, Hyun Jung Koo3
1Division of Cardiology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Background:
We aimed to compare the myocardial ischemic burden assessed using semi-quantitative and quantitative analysis of computed tomography-myocardial perfusion imaging (CT-MPI) with that of single-photon emission computed tomography (SPECT).
Methods:
From 2011 to 2013, 97 patients who underwent CT-MPI and SPECT were evaluated. The extent and severity of perfusion defects were assessed on a 5-point scale using a standard 16-segment model, and were expressed as summed stress score (SSS) and summed difference score (SDS). Receiver operating characteristic (ROC) curves for quantitative parameters were generated for the diagnosis of abnormal perfusion defect (SSS ≥ 4) and presence of ischemia (SDS ≥ 2) on SPECT.
Results:
On CT-MPI, 298 (19.2%) of the 1552 segments showed perfusion abnormalities during stress, whereas perfusion abnormalities were shown in 179 (11.5%) segments on SPECT-MPI. On a per-person basis, there was good agreement, with intraclass correlation coefficients of 0.78 for SSS and 0.72 for SDS. A significant reduction of attenuation in stress and myocardial perfusion reserve index, along with an increase in % defect volume of CT-MPI, were demonstrated as the degree of perfusion defect or ischemia on SPECT increased. On the ROC curves, % defect volume on CT-MPI demonstrated the highest area under the curve: 0.91 for abnormal perfusion defect and 0.89 (all p < 0.001) for the presence of ischemia on SPECT.
Conclusions:
Semi-quantitative analysis of CT-MPI showed good accordance with SPECT. A quantitative approach for CT-MPI, especially % defect volume, may provide additional value in the identification of myocardial perfusion abnormalities.
Clinical Trial Registration:
https://clinicaltrials.gov/ct2/show/NCT01696006.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Quantitative Aspects of Drug-Receptor Interaction
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...