Related Experiment Video
Updated: Jan 31, 2026

Multifocal Electroretinograms
Published on: December 4, 2011
Impact of light conditions on reading ability following multifocal pseudophakic corrections
Georgios Labiris1, Panagiota Ntonti1, Eirini-Kanella Panagiotopoulou1
1Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, Greece, labiris@usa.net.
Purpose:
To examine the impact of light intensity and temperature on reading performance following bilateral pseudophakic multifocal presbyopic correction.
Patients And Methods:
This is a prospective clinic-based trial conducted at the Department of Ophthalmology in the University Hospital of Alexandroupolis, Greece. Three groups of patients were formed (G1: patients with bilateral bifocal implantation, G2: patients with bilateral trifocal implantation, and control group: patients with bilateral pseudophakic monofocal implantation). Reading ability was quantified with the Greek version of MNREAD chart with minimal reading speed at 80 words/min for the following light intensities (25, 50, and 75 Foot-Candles [FC]) and temperatures (3,000, 4,000, and 6,000 K). Preferred light conditions for reading were assessed, as well. ClinicalTrials.gov Identifier: NCT03226561.
Results:
Control group demonstrated significantly lower reading ability at all light combinations with maximal ability at 75 FC and 6,000 K (0.58±0.18 logMAR). Bifocal group presented a light-dependent reading ability that ranged from 0.45±0.08 logMAR (25 FC and 3,000 K) to 0.40±0.11 logMAR (75 FC and 4,000 or 6,000 K). Trifocal participants presented the best reading ability that was light intensity-independent; however, their performance was reduced at 6,000 K. G1 and G2 preferred primarily intermediate light temperature, while control participants preferred cold light temperature.
Conclusion:
Multifocal pseudophakic corrections improve reading ability; however, they present variable efficacy according to the light conditions.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
08:49Impacts of Free-falling Spheres on a Deep Liquid Pool with Altered Fluid and Impactor Surface Conditions
Published on: February 17, 2019
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Distance Corrections
Power Factor Correction
Impact of Groups on Groups
Impact
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...
NMR Spectrometers: Resolution and Error Correction