Clinical application of planar puncture template-assisted computed tomography-guided percutaneous biopsy for small
Zhe Ji1, Guan Wang2, Baoming Chen2
1Department of Radiation Oncology, Peking University Third Hospital, Beijing; China Northern Radioactive Brachytherapy Group, Tangshan People's Hospital, Tangshan, Hebei, PR China.
Aims:
The aims of this study were to evaluate the clinical application of planar puncture template (PPT) in computed tomography (CT)-guided percutaneous needle lung biopsy.
Subjects And Methods:
A total of 56 patients with small pulmonary nodules who received CT-guided percutaneous lung biopsy assisted by PPT were included in the study. Five steps were included in the study: fixing position, CT scanning and designing needle pathway, installing navigation system and template, puncturing fixation needle, and performing biopsy needle insertion and biopsy. The success rate of puncture, pathological results, and complications were analyzed. In addition, the factors that influenced the success rate and complications were analyzed.
Results:
Biopsy was successfully completed in all 56 patients. The nodule diameter was 0.45-3 cm. The fixation needle technique was applied in 47 cases. Biopsy was performed 1 time in 50% of patients and 2 times in 38% of patients. For pathology, only one case showed no positive result, with a puncture success rate of 98%. The diagnostic rate of malignant tumor was 73%. For complications, the incidence of needle tract bleeding was 68%, the incidence of pneumothorax was 30%, and the thoracic drainage was required in two patients. Hemoptysis was observed in two cases. Univariate analysis: The nodule size was related to both the rate of 1-time biopsy and incidence of complications. Smaller nodule was relevant to lower rate of 1-time biopsy (P = 0.01) and higher incidence of complications (P < 0.05). The fixation needle was related to 1-time biopsy rate. The 1-time biopsy rate was significantly higher in patients with fixation needle than those without fixation needle (P = 0.001). Meanwhile, no significant difference was observed in the incidence of complications in different number of fixation needles (P > 0.05).
Conclusions:
PPT-assisted lung biopsy technology can provide high success rate and low complication incidence. It would be helpful to make the puncture procedures more standard for better clinical applications.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
DNA as a Genetic Template
DNA as a Genetic Template
Clinical Applications of Epidermal Stem Cells