Related Experiment Video
Updated: Jan 31, 2026

Optimization of High Grade Glioma Cell Culture from Surgical Specimens for Use in Clinically Relevant Animal Models and 3D Immunochemistry
Published on: January 7, 2014
Clinical efficacy of simplified intravoxel incoherent motion imaging using three b-values for differentiating high-
Takuya Hino1, Osamu Togao1, Akio Hiwatashi2
1Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Abstract:
In this study, we evaluated the efficacy of intravoxel incoherent motion (IVIM)-derived parameters calculated with three b-values in differentiating high-grade gliomas (HGGs) from low-grade gliomas (LGGs) by comparing those calculated with multiple b-values. Ten patients with LGG (ages 35.1±12.1 yrs; 4 males, 6 females) and 21 patients with HGG (ages 60.6±19.1 yrs; 10 males, 11 females) who underwent subsequent surgical resections were examined with both IVIM imaging and histopathological analysis. The IVIM diffusion-weighted imaging was conducted using a single-shot echo planar sequence with 13 b-factors (0, 10, 20, 30, 50, 80, 100, 200, 300, 400, 600, 800, and 1000 sec/mm2) at 3T. In the conventional IVIM analysis, the perfusion fraction (f) and true diffusion coefficient (D) were calculated by biexponential fitting model with 13 b-values. In the simplified method with the selected three b-values (0, 300, and 1000 sec/mm2), D simply corresponds to the slope of a straight line passing through two logarithmic signal intensities (SIs) at the b-values of 300 and 1000 s/mm2, and f corresponds to the difference between the intercept of this line and SI at the b-value of 0 sec/mm2. The maximum f (f-max) and minimum D (D-min) was measured in each tumor. The f-max values calculated with three b-values (12.8±5.9%) were significantly lower than those with 13 b-values (17.3±7.5%, p<0.0001), but a good correlation and agreement were observed between these sets of f-max values (r = 0.79, ICC = 0.87). In the IVIM imaging with both three and 13 b-values, the HGGs showed significantly higher f-max values compared to the LGGs (p<0.001, respectively). The D-min values calculated with three b-values (1.06±0.31 ×10-3 mm2/sec) was not different from those with 13 b-values (1.07±0.33 ×10-3 mm2/sec), and an excellent correlation and agreement were found between them (r = 0.99, ICC = 0.99). The simplified IVIM imaging using three b-values can efficiently differentiate HGGs and LGGs.
Related Concept Videos
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Self-Efficacy

