Impact of mydriasis in fluorescence lifetime imaging ophthalmoscopy
SriniVas R Sadda1,2, Enrico Borrelli1, Wenying Fan1
1Department of Ophthalmology, David Geffen School of Medicine at UCLA, Doheny Eye Center, Los Angeles, CA.
Abstract:
Fluorescence lifetime imaging ophthalmoscopy (FLIO) is a novel technique that measures in vivo autofluorescence intensity decay over time of endogenous fluorophores in the retina. The Heidelberg Engineering FLIO system was used to obtain two 30 degree scans centered on the fovea of both eyes. The FLIO system uses a 473nm blue scanning laser light source and the emitted fluorescence is detected in two wavelengths channels, short and long spectral channels (SSC, LSC). Since the mydriatic status influence the FLIO result, the impact of mydriasis on FLIO need to be clarified. In this prospective, observational study, the impact of mydriasis on measurements from fluorescence lifetime imaging ophthalmoscope (FLIO) images in normal subjects were evaluated. 12 healthy participants (24 eyes) were volunteered and all subjects were scanned twice and the mean fluorescence lifetime (τm) values were computed with dilation and without dilation on different days. Intraclass correlation coefficients (ICC) and coefficients of variation (CV) were calculated from the measured τm in dilated, nondilated and between the dilated and non-dilated setting. Test duration was also compared and correlated with lifetimes in both settings. Repeatability was excellent for both the dilation and non-dilation settings (ICC; 0.967-0.996; 0.926-0.986, respectively). The agreement between the dilation and non-dilation settings, however, were lower (ICC; 0.688-0.970). The τm in the non-dilation setting was significantly longer than in the dilation setting for the SSC (P<0.05). The FLIO test duration in the non-dilation setting was significantly longer than with dilation for the SSC (P <0.05). Although good repeatability in τm measurements between imaging sessions were observed both with and without dilation, the agreement was not as good when comparing dilated with non-dilated measurements. Since FLIO without mydriasis results in longer τm in the SSC and takes a longer time for image acquisition, maximal dilation is recommended for FLIO testing.
Related Concept Videos
Impact of Groups on Groups
Impact
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...
Impact of Groups on Individuals
Impact of Individuals on a Group
Impact of Schemas
Types of Impact
The coefficient of restitution is a metric for understanding the dynamics of impacts. It quantifies the ratio of relative velocity...