A novel method in correcting aberropia using pin hole soft contact lenses: A case report
Lavanya Kalikivayi1, Jithu Ajitha Vilasendran1, Antony Chettupuzha Lonappan2
1Ahalia School of Optometry, Ahalia Foundation Eye Hospital, Palakkad 678557, India.
Abstract:
Aberropia leads to decrease in image quality due to higher order aberrations (HOA). Correction of these HOA poses a great challenge to clinicians. A case report is presented here where a 30 year old male visited with complaints of cloudy vision, diplopia in reduced illumination along with inferior vertical elongation of light during night time in the right eye since 6 years. The unaided visual acuity was found to be 0.0 Log MAR units and near acuity was N6. The patient did not accept any correction in subjective refraction. The aberrometry findings revealed vertical trefoil and vertical coma of -0.33 μm and 0.53 μm in the right eye and -0.07 μm and 0.12 μm in the left eye. Orbscan revealed a difference of 30 μm and 25 μm between the anterior and posterior float for the right and left eye respectively. Due to the significant increase in irregular astigmatism, vertical coma and vertical trefoil in the right eye, rigid gas permeable lenses and Rose K lenses were tried, but the symptoms did not reduce. This was due to the increase in posterior corneal astigmatism as the posterior float was more than 25 μm in the right eye which led to a diagnosis of early keratoconus. As the decrease in pupil size reduces HOA, a pin hole (2.5 mm pupil) soft contact lens was tried which reduced the symptoms. Hence a novel method is proposed to eliminate HOA which corrects aberropia by using pin hole soft contact lenses.
More Related Videos
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
Related Concept Videos
Distance Corrections
Power Factor Correction
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process: