Hybrid control algorithm for flexible needle steering: Demonstration in phantom and human cadaver
Navid Shahriari1,2, Janniko R Georgiadis3, Matthijs Oudkerk1
1University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Groningen, The Netherlands.
Abstract:
Needles are commonly used in the clinic for percutaneous procedures. The outcome of such procedures heavily depends on accurate placement of the needle. There are two main challenges to achieve high accuracy: First, aligning the needle with the targeted lesion, and second, compensating for the deflection of the needle in the tissue. In order to address these challenges, scientists have developed several robotic setups for needle steering. However, the subject is still under research and reliable implementations which can be used in clinical practice are not yet available. In this paper, we have taken some steps in order to bring needle steering closer to practice. A new hybrid control algorithm is developed, which enables us to control a flexible needle by combing base-manipulation and beveled-tip steering methods. A pre-operative path planner is developed which considers the clinical requirements. The proposed method is tested in the lung of a fresh-frozen human cadaver. The work-flow of the experiments are similar to the current clinical practice. Three experimental cases are used to evaluate the proposed steering algorithm. Experimental Case I shows that using the proposed steering algorithm controllability of the needle is increased. In Case II and Case III, the needle is steered in a gelatin phantom and a human cadaver, respectively. The targeting accuracy of 1.35±0.49mm in gelatin phantom and 1.97±0.89mm in cadave is achieved. A feasibility study is performed, in which a fine needle aspiration (FNA) needle is steered in the lungs of a human cadaver under computed tomography guidance. The targeting error for the feasibility study is 2.89±0.22mm. The results suggest that such a robotic system can be beneficial for clinical use and the patient receives less x-ray radiation.
More Related Videos
Related Concept Videos
Hybrid Zones
Trial and Error and Algorithm
Hybridization of Atomic Orbitals I
Hybridization of Atomic Orbitals II
Combinatorial Gene Control
The expression of more than 30,000 genes is controlled by approximately 2000-3000 transcription factors. This is possible because a single transcription factor can recognize more than one regulatory sequence. The specificity in gene...
In-situ Hybridization
Types of probes and labels
A probe is a complementary strand of DNA or RNA that binds to corresponding nucleotide sequences in a cell. Many...