Visual analysis versus quantitative CT analysis of interlobar fissure integrity in selecting emphysematous patients
Alfonso Fiorelli1, Camilla Poggi2, Marco Anile2
1Thoracic Surgery Unit, Università della Campania "Luigi Vanvitelli", Naples, Italy.
Objectives:
The aim of this study is to compare the accuracy of the standard visual scoring of computed tomography (CT) scans with a cloud-based quantitative CT analysis that uses the StratX software, to measure collateral ventilation and, thus, predict lobar atelectasis after valve treatment.
Methods:
This is a retrospective, multicentre study of patients who had previously undergone valve treatment for severe heterogeneous emphysema and whose required fissure integrity ≥90% had been qualitatively scored by visual assessment of CT scans. For this study, all preprocedural CT scans were retrospectively analysed using the StratX software to provide quantitative scores of fissure integrity. The diagnostic accuracies of the visual and quantitative scores for predicting a target lobe volume reduction (TLVR) of ≥350 ml were calculated and statistically compared, as this level of volume reduction can be achieved only with sound fissure integrity. The clinical outcome of TLVR was also evaluated according to the minimal clinically important difference criteria.
Results:
Eighty-three patients were included in the analysis. Of them, 65 of 83 (78%) patients presented with TLVR ≥350 ml. Visual scoring correctly identified the absence of collateral ventilation in 65 of 83 (78%) cases but failed in 18 of 83 (22%) cases. Of these 18 patients, quantitative analysis showed that 16 of 18 (89%) patients did not present completeness of the fissure. The diagnostic accuracy of the quantitative analysis was better than that of the visual analysis (96.4% vs 78.3%; P = 0.0003). Only patients having TLVR ≥350 ml met or exceeded the minimal clinically important difference criteria.
Conclusions:
The quantitative analysis using the StratX software contributed a more objective and efficient evaluation of collateral ventilation that would have improved the selection of emphysematous patients for endobronchial valve treatment in the study population.
More Related Videos
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Qualitative Analysis
For instance, group IV...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Pedigree Analysis
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...