A multi-functional minimally-disruptive portable electrochemical system based on yeast/Co3O4/Au/SPEs for blood lead
Jing Nie1, Bin He1, Yu-Jiao Zang1
1National-Municipal Joint Engineering Laboratory for Chemical Process, Intensification and Reaction, School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044, China.
Abstract:
A minimally-disruptive portable electrochemical system is constructed by combining a hand-held syringe as reservoir with disposable screen-printed electrodes (SPEs) modified with a simple and efficient yeast/Co3O4/Au material for lead determination by a square-wave voltammetry (SWV) method. Not only can it preserve the operation and advantages of the conventional electrochemical procedure, but it also integrates sampling, filtering and analysis to make the determination of lead convenient and effective at higher and lower concentration levels. This is the first report of a microbial biosensor based on active yeast crosslinked to Co3O4/Au particles using glutaraldehyde as the crosslinking agent. The determination process is simplified by introducing a fiber filter and takes only 150 s with the developed system, which illustrates its simplicity, speed and detection accuracy. Also, the design shows a wide log-linear dynamic range (LDR) from 10-8 to 10-14 g·L-1, with a limit of detection (LOD) of 3.45 × 10-15 g·L-1 (S/N = 3). Additionally, the proposed system was used to determine lead in blood samples, which demonstrated the potential of this biosensor for use in practical applications. Furthermore, this study provides a basis for the development of microscale blood devices for lead measurement.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Yeast Signaling
Characteristics and Functions of Blood
The primary function of blood is to transport oxygen and carbon dioxide between tissues and the lungs. Oxygenated blood is bright red, while oxygen-depleted blood is darker. It also carries...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Exponential Functions with Base e