Related Experiment Video
Updated: Jan 31, 2026

Simple and Fast Rolling Circle Amplification-Based Detection of Topoisomerase 1 Activity in Crude Biological Samples
Published on: December 2, 2022
Rolling circle amplification integrated with suspension bead array for ultrasensitive multiplex immunodetection of
Min Gao1, Hong Lian1, Longjiao Yu1
1MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian, 361005, People's Republic of China.
Abstract:
Multiplex detection of ultra-low abundant tumor markers is extremely important for early diagnosis and therapy evaluation. Herein, an ultrasensitive multiplex immunoassay was developed by combination of rolling circle amplification (RCA) and suspension bead array (SBA) technology. Based on a conventional sandwich-type immunoreaction on beads, the detection antibodies were conjugated with DNA primers, so RCA could be implemented to generate long-stranded DNA with abundant repeated sequences allowing for hybridization with fluorochrome-labeled oligonucleotide probes. Thus the fluorescence signal of immunocomplexes on the encoded beads can be greatly enhanced. Using the as-developed immuno-RCA suspension bead array (iRCA-SBA), simultaneous analysis of multiple tumor markers was achieved with the limits of detection of 3.1 pg/mL (∼0.1 pM) for prostate specific antigen (PSA), 9.1 pg/mL (∼50 fM) for carcinoembryonic antigen (CEA), and 0.66 pg/mL (∼9 fM) for α-fetoprotein (AFP), which are two to three orders of magnitude lower than those obtained by the conventional SBA method. The dynamic range were 4.5, 4.7, and 5.5 orders of magnitude for PSA, CEA, and AFP, respectively. Tests on clinical serum samples demonstrate that the tumor marker concentrations measured by the newly developed iRCA-SBA assay agreed well with those obtained by the conventional SBA method. These results indicate that the iRCA-SBA assay significantly increased the detection sensitivity and dynamic range without sacrificing the reliability and accuracy of conventional SBA. Upon the integration with iRCA, SBA could find more applications in the detection of low abundance protein biomarkers for early diagnosis of cancer and other diseases.
Related Concept Videos
Circles
Rolling Without Slipping
Rolling With Slipping
An object's rolling motion is characterized by its rotation around its axis, while linear motion refers to the object's translational motion along a surface. Frictional forces can...
Rolling Resistance
For instance, imagine a hard cylinder rolling on a comparatively soft surface. The cylinder's weight compresses the surface beneath it. As the cylinder moves, the material in front of it slows down due to...
Mohr's Circle for Moments of Inertia: Problem Solving
Consider a rectangular beam. The moments of inertia of the beam about the x and y axis are 2.5(107) mm4 and 7.5(107) mm4, respectively. The product of inertia is 1.5(107) mm4. Determine the principal moments of inertia and the orientation of the major and...
Rolling Resistance: Problem Solving

