Revealing Nanoscale Morphology of the Primary Cilium Using Super-Resolution Fluorescence Microscopy

Joshua Yoon1, Colin J Comerci2, Lucien E Weiss3

  • 1Department of Applied Physics, Stanford University, Stanford, California; Department of Chemistry, Stanford University, Stanford, California.

Biophysical Journal
|January 2, 2019
PubMed

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.5K
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
21.1K
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
13.4K
Microbial Morphologies01:29

Microbial Morphologies

Bacterial and archaeal cells exhibit remarkable diversity in shape and structure, critical in their adaptability and functionality. Among bacteria, the most commonly observed shapes include cocci and bacilli. Cocci are spherical and may exist singly or in groupings such as pairs (diplococci), chains (streptococci), clusters (staphylococci), or tetrads. Bacilli, in contrast, are rod-shaped and can also occur as single cells, in pairs, or chains, depending on their environmental and genetic...
2.7K
Chromatographic Resolution01:15

Chromatographic Resolution

In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
2.1K
Primary Active Transport01:47

Primary Active Transport

In contrast to passive transport, active transport involves a substance being moved through membranes in a direction against its concentration or electrochemical gradient. There are two types of active transport: primary active transport and secondary active transport. Primary active transport utilizes chemical energy from ATP to drive protein pumps that are embedded in the cell membrane. With energy from ATP, the pumps transport ions against their electrochemical gradients—a direction...
198.3K