Related Experiment Video
Updated: Jan 31, 2026

Induction and Phenotyping of Acute Right Heart Failure in a Large Animal Model of Chronic Thromboembolic Pulmonary Hypertension
Published on: March 17, 2022
Effects of Acute GLP-1 Infusion on Pulmonary and Systemic Hemodynamics in Patients With Heart Failure: A Pilot Study
Sophie J Clarke1, Stephen Pettit2, Joel P Giblett2
1Department of Cardiovascular Medicine, University of Cambridge, Cambridge, United Kingdom.
Purpose:
Cardiovascular-safety studies assessing glucagon-like peptide (GLP)-1 receptor agonists and dipeptidyl peptidase 4 inhibitors have provided inconsistent data on the risk for developing heart failure. Animal studies have shown that GLP-1 is a vasodilator; if confirmed in humans, this may ameliorate heart failure symptoms.
Methods:
In a single-center, observational pilot study, we recruited 10 patients with advanced heart failure undergoing right heart catheterization, and we recorded pulmonary hemodynamic measures, including cardiac output calculated by thermodilution and the indirect Fick method before and after a 15-minute continuous infusion of native GLP-1 (7-36) NH2.
Findings:
There was a neutral effect of GLP-1 on all pressure and hemodynamics indices as derived by cardiac output calculated by thermodilution. However, there was a small but consistent reduction in cardiac output as calculated by the indirect Fick method after GLP-1 infusion (baseline, 4.0 [1.1] L/min vs GLP-1, 3.6 [0.9] L/min; P = 0.003), driven by a consistent reduction in mixed venous oxygen saturation after GLP-1 infusion (baseline, 62.2% [7.0%] vs GLP-1, 59.3% [6.8%]; P < 0.001), whereas arterial saturation remained constant (baseline, 96.8% [3.3%] vs GLP-1, 97.0% [3.2%]; P = 0.34). This resulted in an increase in systemic vascular resistance by Fick (baseline, 1285 [228] dyn · s/cm5 vs GLP-1, 1562 [247] dyn · s/cm5; P = 0.001).
Implications:
Acute infusion of GLP-1 has a neutral hemodynamic effect, when assessed by thermodilution, in patients with heart failure. However, GLP-1 reduces mixed venous oxygen saturation. ClinicalTrials.gov identifier: NCT02129179.
More Related Videos
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
Related Concept Videos
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Heart Failure II: Pathophysiology
Pathophysiology of Heart Failure
Heart Failure I: Introduction