Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Reduction of fluoroscopy dose for cardiac electrophysiology procedures: A feasibility and safety study
F Plank1, B Stowasser2, D Till2
1Medical University of Innsbruck, University Clinic of Internal Medicine III / Cardiology and Angiology, Innsbruck, Austria.
Background:
Exposure to high doses of radiation during cardiac interventional procedures is associated with increased rates of cataract and cancer in patients and staff members. Thus, reduction of radiation is recommended by international medical societies. The aim of this study was to evaluate, if the lowest reasonable fluoroscopic acquisition setting for electrophysiological procedures using a novel X-ray detector operated at a minimum detector entrance dose per fluoroscopy pulse is feasible and safe.
Methods:
641 consecutive patients (407 m/234f) underwent ablation procedures at our institution between August 2015 and December 2017. All ablations were performed using an Artis Q.zen X-ray system (Siemens, Germany). The first 308 patients were treated using the conventional dose program ("fluoroscopy zen standard"), from October 2016 until December 2017 another 333 patients underwent ablations using the optimized X-ray dosing program "fluoroscopy zen ULD". For the standard program fluoroscopy dose was set to 18nGy/f, for the minimized dosing program the dose was set to 6nGy/pulse and could be increased to 10 or 15 nGy/pulse manually.
Results:
A total of 213 AV-node reentry tachycardia (AVNRT), 73 accessory pathways (AP), 71 atrial flutter and 284 atrial fibrillation (AF) ablation procedures were performed. Pulmonary vein isolation was performed using an electroanatomic mapping system (CARTO, Biosense Webster, USA) in 117 or a cryoballoon (Cryocath Medtronic, USA) in 167 patients. Total area dose could be reduced in all groups by a mean of 74.7% (4201.4μGym² vs. 1063.7μGym²), with a relative reduction of 73.1% for left atrial and 78.0% for right sided ablations. Total fluoroscopy time, procedure duration, acute ablation success, recurrence rate and complications remained unchanged.
Conclusion:
Fluoroscopy dose could be significantly reduced using an optimized X-ray dosing program in a novel X-ray detector without increasing total fluoroscopy time and without alterations of the incidence of recurrences or complications.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
06:40Impact of Intracardiac Neurons on Cardiac Electrophysiology and Arrhythmogenesis in an Ex Vivo Langendorff System
Published on: May 22, 2018
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Cardiac Catheterization I: Pre-Procedure Overview
Bioavailability Study Design: Single Versus Multiple Dose Studies
Survey Safety
Oxidation-Reduction Reactions
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...