Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Assessment of Diffusion and Perfusion01:17

Assessment of Diffusion and Perfusion

1.6K
Understanding and evaluating diffusion and perfusion is critical in assessing a patient's respiratory and circulatory health. These processes play key roles in maintaining the body's internal environment, ensuring that tissues receive adequate oxygen while waste products are efficiently removed.
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
1.6K
Geometric Mean01:15

Geometric Mean

4.0K
The mean is a measure of the central tendency of a data set. In some data sets, the data is inherently multiplicative, and the arithmetic mean is not useful. For example, the human population multiplies with time, and so does the credit amount of financial investment, as the interest compounds over successive time intervals.
In cases of multiplicative data, the geometric mean is used for statistical analysis. First, the product of all the elements is taken. Then, if there are n elements in the...
4.0K
Geometric Sequences01:30

Geometric Sequences

284
In systems where values diminish by a constant proportion at each stage, the resulting sequence follows a geometric structure. Each new value in the sequence is obtained by applying a fixed multiplier to the preceding term. This regular, proportional decline type is often used to represent processes involving gradual loss, such as energy dissipation or reduction in amplitude over time.When analyzing the total effect of such a process across unlimited iterations, the series of values is referred...
284
Diffusion01:12

Diffusion

218.1K
Diffusion is the passive movement of substances down their concentration gradients—requiring no expenditure of cellular energy. Substances, such as molecules or ions, diffuse from an area of high concentration to an area of low concentration in the cytosol or across membranes. Eventually, the concentration will even out, with the substance moving randomly but causing no net change in concentration. Such a state is called dynamic equilibrium, which is essential for maintaining overall...
218.1K
Diffusion01:21

Diffusion

6.4K
Diffusion is a type of passive transport. In passive transport, a substance tends to move from an area of high concentration to an area of low concentration until the concentration is equal across the space. For example, take the diffusion of substances through the air. When someone opens a perfume bottle in a room filled with people, the perfume is at its highest concentration in the bottle and is at its lowest at the edges of the room. The perfume vapor will diffuse, or spread away, from the...
6.4K
Accelerators01:17

Accelerators

287
Accelerators in concrete serve as admixtures to speed up the hardening process, enabling the concrete to achieve early strength faster. Although accelerators do not necessarily impact the time it takes concrete to set, they reduce this time in practice. A common accelerator is calcium chloride, which is particularly useful for hastening early strength development in cold weather or for rapid repair jobs that require quick heat generation after mixing.
The effectiveness of calcium chloride can...
287

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Magnetic Resonance Imaging at 14 Tesla of Prostate Biopsies Obtained after Prostatectomy.

NMR in biomedicine·2026
Same author

Correction to: Preoperative risk assessment of endometrial cancer using histogram analysis of weighted and quantitative MRI images.

Abdominal radiology (New York)·2026
Same author

Self-Supervised Deep Learning Framework for Rician Distribution Based Denoising and Modeling of Multi-b Prostate Diffusion MRI.

Magnetic resonance in medicine·2026
Same author

Head Motion Correction Based on Pilot Tone Signals in MRI: A Referenceless Method.

IEEE transactions on medical imaging·2026
Same author

Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues.

Magnetic resonance in medicine·2026
Same author

Motion-compensated diffusion encoding gradients for segmented thick-slab 3D magnetic resonance diffusion-weighted imaging of the brain.

Medical physics·2026

Related Experiment Video

Updated: Jan 31, 2026

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
17:06

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

Published on: November 8, 2012

27.0K

Accelerated Segmented Diffusion-Weighted Prostate Imaging for Higher Resolution, Higher Geometric Fidelity, and

Pelin Aksit Ciris, Jr-Yuan George Chiou1, Daniel I Glazer1

  • 1Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA.

Investigative Radiology
|January 3, 2019
PubMed
Summary

This study introduces a faster, more precise magnetic resonance imaging technique for the prostate. By using a segmented approach, the researchers achieved sharper images with less distortion compared to standard methods. This new scan also allows doctors to measure blood flow within tissues, providing more detailed information for diagnosis.

Keywords:
magnetic resonance imagingintravoxel incoherent motionecho-planar imagingdiagnostic radiology

Frequently Asked Questions

More Related Videos

Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration
06:14

Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration

Published on: May 9, 2020

9.0K
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

23.2K

Related Experiment Videos

Last Updated: Jan 31, 2026

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
17:06

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

Published on: November 8, 2012

27.0K
Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration
06:14

Induction of Diffuse Axonal Brain Injury in Rats Based on Rotational Acceleration

Published on: May 9, 2020

9.0K
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

23.2K

Area of Science:

  • Medical imaging physics within diagnostic radiology
  • Prostate diffusion-weighted imaging clinical applications

Background:

Current prostate magnetic resonance imaging often suffers from significant geometric distortion and limited spatial resolution. These technical shortcomings hinder the accurate identification of small lesions within the gland. Standard single-shot echo-planar imaging techniques frequently struggle with susceptibility artifacts near tissue boundaries. No prior work had resolved these limitations while simultaneously enabling advanced perfusion modeling. That uncertainty drove the development of new acquisition strategies to enhance diagnostic accuracy. Prior research has shown that segmented approaches can mitigate some of these common image quality issues. However, the integration of these methods into routine clinical workflows remains challenging for many centers. This gap motivated the current investigation into optimized segmented diffusion-weighted sequences for prostate evaluation.

Purpose Of The Study:

The aim of this study was to enhance the geometric fidelity and spatial resolution of multi-b diffusion-weighted magnetic resonance imaging of the prostate. Researchers sought to address the limitations inherent in conventional single-shot echo-planar imaging techniques. These standard methods often produce distorted images that complicate the precise localization of suspicious tissue. The team developed an accelerated segmented sequence to overcome these specific technical challenges. They also intended to enable the estimation of tissue perfusion using the intravoxel incoherent motion model. This motivation stemmed from the need for more comprehensive diagnostic information during multiparametric prostate examinations. The study evaluates whether a reduced field of view combined with increased diffusion weightings can improve clinical outcomes. This investigation provides a systematic assessment of the proposed sequence in a patient cohort.

Main Methods:

Review approach involved developing an accelerated segmented sequence for multiparametric magnetic resonance examinations. The team evaluated this protocol in twenty-five patients to assess performance. Investigators utilized an endorectal coil to capture a restricted field of view during the scans. They increased the quantity of sampled diffusion weightings to facilitate advanced perfusion modeling. The team compared apparent diffusion coefficient measurements against standard single-shot echo-planar imaging benchmarks. This design focused on quantifying improvements in spatial resolution and geometric fidelity. The researchers applied the intravoxel incoherent motion model to derive perfusion fractions from the collected data. Statistical analysis confirmed the reliability of the proposed sequence against established clinical standards.

Main Results:

Key findings from the literature indicate that the segmented method achieves a two-fold improvement in spatial resolution. The study reports a greater than three-fold enhancement in geometric fidelity compared to single-shot echo-planar imaging. Apparent diffusion coefficient values showed excellent agreement with conventional scans, yielding correlation coefficients of 0.91 at 500 s/mm and 0.89 at 1400 s/mm. The researchers measured an intravoxel incoherent motion perfusion fraction of 4.0% in the normal peripheral zone. In the normal transition zone, the perfusion fraction was recorded at 6.6%. Suspected tumor lesions exhibited a perfusion fraction of 4.4%. These values were derived from the increased number of sampled diffusion weightings. The results confirm that the accelerated sequence provides both high-quality imaging and concurrent perfusion quantification.

Conclusions:

The authors propose that their segmented acquisition strategy successfully enhances both spatial resolution and geometric fidelity. This approach offers a reliable alternative to traditional single-shot techniques for prostate assessment. Synthesis and implications suggest that the method facilitates concurrent estimation of intravoxel incoherent motion parameters. The results demonstrate excellent agreement between the novel sequence and conventional imaging benchmarks. Clinicians may benefit from the improved anatomical detail provided by this accelerated scanning protocol. The study highlights the potential for more robust tissue characterization in routine multiparametric examinations. Future clinical utility appears promising given the observed performance metrics across different b-factor ranges. These findings confirm that segmented imaging provides a viable path toward higher quality prostate diagnostics.

The researchers propose that the segmented method utilizes a reduced field of view and increased diffusion weightings. This allows for the simultaneous calculation of intravoxel incoherent motion perfusion fractions, unlike conventional single-shot echo-planar imaging which lacks this specific capability.

The authors utilized an endorectal coil to acquire a reduced field of view. This hardware component is necessary to achieve the reported two-fold improvement in spatial resolution compared to standard whole-pelvis imaging techniques.

The researchers state that the segmented approach is necessary to reduce susceptibility artifacts. This technical requirement minimizes geometric distortion, providing a three-fold improvement in fidelity compared to single-shot echo-planar imaging, which is highly sensitive to magnetic field inhomogeneities.

The authors employed the intravoxel incoherent motion model to process the multi-b diffusion data. This mathematical framework allows the extraction of perfusion fractions from the signal decay, distinguishing between tissue diffusion and microvascular blood flow.

The researchers measured apparent diffusion coefficients to validate the novel sequence. They reported high correlation coefficients of 0.91 and 0.89 for different maximum b-factors, indicating excellent agreement with conventional scan benchmarks.

The authors propose that their method allows for more accurate tumor lesion assessment. By providing clearer anatomical images and perfusion data, the technique may improve the detection of suspected prostate abnormalities during routine clinical exams.