Related Experiment Video
Updated: Jan 31, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Single-centre first experience with transapical transcatheter mitral valve replacement with an apical tether: factors
Gry Dahle1,2, Thomas Helle-Valle3, Jan Otto Beitnes3
1Department of Cardiothoracic Surgery, Oslo University, Oslo, Norway.
Objectives:
Transcatheter mitral valve replacement has recently been introduced as an alternative treatment option for severe mitral regurgitation. We present our single-centre first experience with screening and implantation outcomes.
Methods:
Twenty-five patients with mitral regurgitation grades 3 and 4 were screened based on study inclusion/exclusion criteria, echocardiography and computed tomography imaging. All patients were evaluated by the centre's Heart Team, followed by the Tendyne's internal screening process. Patients who failed the screening criteria were considered for alternative treatments.
Results:
Of the 25 patients screened for transcatheter mitral valve replacement, 14 patients failed screening and 11 patients passed. The patients who failed screening were more often older, were women and were smaller in stature than those who passed screening. The main reason for patients to fail screening changed during the study from large annular dimensions to a small predicted neo-left ventricular outflow tract. Eight of the 11 patients who passed screening were treated using the Tendyne device, and 3 patients required alternate treatments due to urgency including 1 MitraClip procedure and 2 surgical repairs. Of the 14 patients who failed the screening, 5 patients had open surgery (4 patients received mitral valve repair and 1 mitral valve replacement). All 8 patients who underwent the Tendyne procedure were successfully treated without mortality during the observation time.
Conclusions:
Transcatheter mitral valve replacement is an effective and safe treatment for well-selected patients with symptomatic mitral regurgitation. For patients who fail the screening process, the MitraClip procedure or open surgical valve repair are feasible.
More Related Videos
07:42An Image Guided Transapical Mitral Valve Leaflet Puncture Model of Controlled Volume Overload from Mitral Regurgitation in the Rat
Published on: May 19, 2020
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Bioavailability: Influencing Factors
Factors Influencing Microbial Growth: pH
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...