Related Experiment Video
Updated: Jan 31, 2026

Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis
Published on: September 22, 2023
Development of an aperture-type radiation regulator for shielding against secondary radiation from x-ray tubes and
Bon-Yeoul Koo1, Hyoun-Joong Kong2,3
1Department of Biomedical Engineering, Graduate School, Chungnam National University, Daejeon 35015, Republic of Korea.
Abstract:
During computed tomography (CT) scans, radiation scatters in all directions, increasing radiation exposure. In this study, an aperture-type radiation regulator was developed to provide shielding against secondary radiation from the x-ray tube and collimator in CT. To evaluate the usefulness of the developed aperture-type radiation regulator, (1) spatial dose distribution within the CT room was measured, (2) dose intensity at 1 m from the isocenter was compared, (3) absorbed dose in the nearby organs was evaluated using a human equivalent phantom, and (4) noise, CNR, and SNR were compared for assessment of image quality. The results showed that the developed aperture-type radiation regulator reduced the intensity of secondary radiation by approximately 25% in front of the gantry and 15% to the rear of the gantry. The maximum dose distribution on 10 μGy was reduced by approximately 18% in front of the gantry and 12% in the rear. In addition, when the neck and head were scanned, the absorbed dose in the chest decreased by 25% and 40%, respectively, and noise was reduced by 3.3%-4.5% for different phantoms. Evaluation of abdominal CT images showed 18% noise reduction, with 27% and 28% increases in the signal-to-noise and contrast-to-noise ratios, respectively. These results confirmed that the proposed aperture-type radiation regulator can reduce radiation exposure without affecting primary radiation that creates medical images. The results also confirmed that the radiation regulator effectively improves the quality of medical images.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Absorption of Radiation
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Generating Electromagnetic Radiations
Momentum And Radiation Pressure