Related Experiment Video
Updated: Jan 31, 2026

Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
Published on: October 27, 2020
Nondestructive Assessment of Glycosaminoglycans in Engineered Cartilages Using Hexabrix-Enhanced Micro-Computed
Long Hao Jin1,2, Byung Hyune Choi3, Young Jick Kim4
11Department of Orthopedic Surgery, School of Medicine, Ajou University, 206 World Cup-ro, Yeongtong-gu, Suwon, 16499 Korea.
Abstract:
It is very useful to evaluate the content and 3D distribution of extracellular matrix non-destructively in tissue engineering. This study evaluated the feasibility of using micro-computed tomography (µCT) with Hexabrix to measure quantitatively sulfated glycosaminoglycans (GAGs) of engineered cartilage. Rabbit chondrocytes at passage 2 were used to produce artificial cartilages in polyglycolic acid scaffolds in vitro. Engineered cartilages were incubated with Hexabrix 320 for 20 min and analyzed via µCT scanning. The number of voxels in the 2D and 3D scanning images were counted to estimate the amount of sulfated GAGs. The optimal threshold value for quantification was determined by regression analysis. The 2D µCT images of an engineered cartilage showed positive correlation with the histological image of Safranin-O staining. Quantitative data obtained with the 3D µCT images of 14 engineered cartilages showed strong correlation with sulfated GAGs contents obtained by biochemical analysis (R2 = 0.883, p < 0.001). Repeated exposure of engineered cartilages to Hexabrix 320 and µCT scanning did not significantly affect cell viability, total DNA content, or the total content of sulfated GAGs. We conclude that µCT imaging using Hexabrix 320 provides high spatial resolution and sensitivity to assess the content and 3D distribution of sulfated GAGs in engineered cartilages. It is expected to be a valuable tool to evaluate the quality of engineered cartilage for commercial development in the future.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Glycosaminoglycans
GAGS are found in the extracellular matrix of vertebrates, invertebrates, and bacteria. Due to their polar nature they attract water, and serve as excellent lubricants or shock absorbers in an animal body.
Hyaluronic...
Imaging Studies III: Computed Tomography
What is Genetic Engineering?
Self-Evaluation: Self-Enhancement and Self-Verification
Growth of Cartilage and Bone Tissue