Related Experiment Video
Updated: Jan 31, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Quantitative magnetic resonance imaging assessment of lateral atlantoaxial joint meniscoid composition: a validation
Scott F Farrell1,2,3, Peter Stanwell4, Jon Cornwall5,6
1RECOVER Injury Research Centre, NHMRC Centre for Research Excellence in Recovery Following Road Traffic Injuries, The University of Queensland, Brisbane, Australia. scott.farrell@uq.edu.au.
Purpose:
Lateral atlantoaxial (LAA) joint meniscoid composition may have clinical significance in patients following neck trauma. However, the existing method of radiologically assessing meniscoid composition has an inherent element of subjectivity, which could contribute to measurement variability. The present study sought to investigate the accuracy of two-point Dixon fat/water separation MRI as a quantitative assessment of LAA joint meniscoid composition.
Methods:
Sixteen LAA joint meniscoids were excised from four cadavers (mean [SD] age 79.5 [3.7] years; one female) following cervical spine MRI (two-point Dixon, T1-weighted VIBE and T2-weighted SPACE sequences). Composition of LAA joint meniscoids was undertaken by (1) histological examination by light microscopy, (2) calculation of fat fraction by Dixon MRI (both in-phase/opposed-phase and fat/water methods), and (3) the existing method of considering VIBE and SPACE signal intensities. Analysis was performed using the kappa statistic with linear weighting.
Results:
Microscopy revealed three, five, and eight meniscoids to be composed of adipose, fibroadipose, and fibrous tissues, respectively. Dixon sequence MRI classified 11 of these meniscoids correctly, with 'substantial' level of agreement (In-phase/Opp-phase kappa statistic = 0.78 [95% CI 0.38, 1.17]; fat/water kappa statistic = 0.72 [95% CI 0.32, 1.11]). Level of agreement between microscopy and the VIBE and SPACE method was 'slight' (kappa statistic = 0.02 [95% CI - 0.34, 0.38]).
Conclusions:
Findings suggest that Dixon fat/water separation MRI may have superior utility in the assessment of LAA joint meniscoid composition than the existing method of considering VIBE and SPACE signal intensities. These slides can be retrieved under Electronic Supplementary Material.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Resonance
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...

