Related Experiment Video
Updated: Jan 31, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
The development of new image receptor-holding instruments with appropriate horizontal X-ray beam angulation for
Peerapong Wamasing1,2, Hiroshi Watanabe1, Yumi Tsuchida1
11 Department of Oral and Maxillofacial Radiology, Tokyo Medical and Dental University , Tokyo , Japan.
Objectives:
This study aimed to develop new image receptor-holding instruments with appropriate horizontal X-ray beam angulation, based on the anatomical data of posterior region interproximal surfaces derived from archived CT images.
Methods:
CT images of 92 patients with sound upper and lower dental arches were collected from our CT database and analyzed to determine the angles between the tangential interproximal contact line and the central groove line of posterior teeth. The average angle for each site was calculated and used to modify instruments using a three-dimensional printer. The utilities of the conventional and the modified instruments for viewing proximal surfaces were compared using two dry skulls.
Results:
The right and left sides of each site, except for the lower second premolar and first molar sites, did not differ significantly. The difference between the sites was 2.0°; hence, we calculated mean values for the two sides at each site. In the maxilla, the angles of the first and second premolar, second premolar and first molar, and first and second molar to the groove line were 83.9° (±5.4°), 84.4° (±3.9°), 81.6° (±5.1°), while those in the mandible were 85.0° (±9.2°), 85.0° (±4.0°), and 90.6° (±4.9°), respectively. The holding instruments modified to 80° demonstrated better proximal viewing ability in the upper molar region than conventional instruments.
Conclusions:
The mean angles of the interproximal surfaces were determined from CT data. The image receptor holding-instruments were modified according to these angles to allow appropriate X-ray angulation, which facilitated improved observation of the proximal surfaces of teeth in the posterior region in this pilot in vitro study.
Related Concept Videos
Shear on the Horizontal Face of a Beam Element
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...

