Related Experiment Video
Updated: Jan 31, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed
Jian Xu1, Xiaolong He2, Huawei Xiao1
1Department of Radiology, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, Zhejiang, China (mainland).
Abstract:
BACKGROUND The aim of this study was to compare the metrics of volume computed tomography index (CTDIvol) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL AND METHODS A total of 157 patients underwent head CT examination were enrolled in this retrospective study. Pearson correlation analysis and linear regression correlation analysis were performed to observe the correlation between the dose metrics of CTDIvol and SSDEaver versus tube current product (mAs) and water equivalent diameter (WED). Correlated factors of CTDIvol and SSDEaver were analyzed by multivariate linear stepwise regression analysis. RESULTS A sum of 4239 data settings were measured: slices with WED >16 cm was 71.05%, and the slices with f <1 was 72.64%. The average value of the absolute difference between WED and the diameter of AAPM head phantom was 2.24±1.42 cm. Statistically significant difference was found between the values of CTDIvol and SSDEaver (P=0.000). The dispersion degree of the CTDIvol values was greater than that of SSDEaver. Strong positive correlation was shown between CTDIvol and mAs (P=0.000), as well as CTDIvol and WED (P=0.000). Strong positive correlation was shown between SSDEaver and mAs (P=0.000), and moderate correlation for SSDEaver and WED (P=0.000). Both the metrics of mAs and WED were included in the multivariate linear stepwise regression equation to observe the effect of related factors on the value of SSDEaver. CONCLUSIONS SSDEaver with better representative can reproduce the radiation dosage of the specific adult patients in head CT examination.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Dose Size and Dosing Frequency: Determination Methods
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Dose-Response Relationship: Selectivity and Specificity