Related Experiment Video
Updated: Jan 31, 2026

Standard Operating Procedure for Lyssavirus Surveillance of the Bat Population in Taiwan
Published on: August 27, 2019
Detection of Pseudogymnoascus destructans on Wisconsin Bats During Summer
Jeffrey J Huebschman1, Samantha A Hoerner1, J Paul White2
11 Department of Biology, University of Wisconsin-Platteville, Platteville, Wisconsin 53818, USA.
Abstract:
White-nose syndrome (WNS) affects bats primarily in winter, with Pseudogymnoascus destructans, the fungus that causes WNS, growing on bats in colder climates as they are hibernating. As a result, nearly all disease investigations have been conducted on bats in the winter or as they are emerging in spring. Although P. destructans has been detected on bats during the summer season, the seasonal dynamics of infection during this period remain poorly understood. To test for the presence of P. destructans during the summer season, we sampled bats that were free flying from June 2017 to September 2017 and also sampled bats from a maternity roost in August and outside a known hibernaculum in September. We collected skin swabs from the muzzle and forearm of bats, and using real-time PCR methods, we detected P. destructans DNA on 16% (12/76) of bats sampled in Wisconsin, US, including juvenile little brown bats (Myotis lucifugus) from bat house maternity roosts, and free-flying adult bats of two species captured in June, the little brown bat and the migratory eastern red bat (Lasiurus borealis). These data illustrated the potential for P. destructans to be transferred and dispersed among bats during the summer and highlighted the complex seasonal dynamics associated with this pathogen.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

