Related Experiment Video
Updated: Jan 31, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Reporting of light irradiation conditions in 300 laboratory studies of resin-composites
David C Watts1, Christina Kaiser2, Catherine O'Neill3
1School of Medical Sciences and Photon Science Institute, University of Manchester, UK.
Objective:
To evaluate how the light delivered to resin-composites was described in recent articles.
Method:
PubMed was searched for 300 articles published between January 2017 and May 2018 with keywords relating to photocuring of dental materials. The articles examined a wide range of resin-composite properties and performance. For each article, the information provided about the light curing unit (LCU), the light curing conditions and the characteristics and quantity of the light used in the study were recorded. Specifically, the type of LCU used; the irradiance; how the irradiance was measured; the exposure times; whether the light energy (radiant exposure) received by the specimen was determined, or if only the light output at the LCU tip was measured; whether the distance between the tip of the LCU and the specimen was reported; and whether the emission spectrum from the LCU was reported. Where possible, the resin manufacturer's minimum energy requirement (MER: the product of the recommended minimum exposure time and irradiance) was compared to the radiant exposure delivered to the specimen.
Results:
Of the 300 articles examined, 217 were published in 2017 and 83 in 2018. Of these articles, 130 (43%) were found in open access journals, and 170 (57%) were in subscription-based journals. The name of the LCU used was not provided in 31 articles, 14 articles did not provide the exposure time, and 227 articles did not report the distance to the specimen. An irradiance value was reported in 231 articles, but this was the irradiance received by the specimen in only 48 instances. The emission spectrum from the LCU was reported in 15 articles. There was a large range in the radiant exposures from below 10J/cm2 to greater than 100J/cm2.
Significance:
The majority of articles from 2017 and early 2018 did not include sufficient description of the characteristics and quantity of the light received by the resin-composite specimens to allow the study to be replicated. It is recommended that future articles should report: (1) the identity of the LCU used; (2) the radiant exposure received by the specimen (J/cm2); and (3) appropriate reference to the emission spectrum from the LCU.
More Related Videos
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
16:30Application of Light-cured Dental Adhesive Resin for Mounting Electrodes or Microdialysis Probes in Chronic Experiments
Published on: July 30, 2007
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Composite Bodies
Composite bodies have widespread applications in mechanical engineering, from automobiles to aircraft to rockets. For example, an automobile wheel comprises...
Composition of Blood
Formed elements constitute the remaining 45% of the blood volume. These...