Related Experiment Video
Updated: Jan 31, 2026

Electrochemical Detection of Deuterium Kinetic Isotope Effect on Extracellular Electron Transport in Shewanella oneidensis MR-1
Published on: April 16, 2018
Assessment of Repeatability in Supercritical Fluid Chromatography with Electrochemical Detection Based on the ISO
Kazuhiro Yamamoto1, Akira Kotani1, Yuzuru Hayashi2
1School of Pharmacy, Tokyo University of Pharmacy and Life Sciences.
Abstract:
The present study proposes a method for the assessment of repeatability in supercritical fluid chromatography with electrochemical detection (SFC-ECD), based on the ISO 11843 part 7 (ISO 11843-7:2018) which can theoretically provide detection limits and standard deviation (S.D.) through the stochastic properties of baseline noise without repetitive measurements of real samples. On the baseline noise of SFC-ECD, large-amplitude and periodic noises with less than 0.05 Hz were observed, and the power spectrum of the baseline noise showed 1/f fluctuation (f = frequency). It was found that the present power spectrum analysis, according to the law of error propagation, can provide suitable noise parameters to calculate S.D. of baseline noise and a relative S.D. (RSD) of peak area by ISO 11843-7. The chromatographic determinations of α-, β-, γ- and δ-tocopherol have been taken as examples. In the present SFC-ECD, the RSDs of peak areas for α-, β-, γ- and δ-tocopherol obtained by ISO 11843-7 were within 95% confidence intervals of the RSD of them obtained by repetitive measurements (n = 6). Thus, we found that ISO 11843-7 is applicable to the assessment of repeatability in SFC-ECD for determining tocopherols without repetitive measurements.
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
The Fluid Mosaic Model
Interfacial Electrochemical Methods: Overview
Affinity Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...