Automated Titration of Vasopressor Infusion Using a Closed-loop Controller: In Vivo Feasibility Study Using a Swine

Alexandre Joosten1, Amélie Delaporte, Brenton Alexander

  • 1From the Department of Anesthesiology (A.J., A.D.) the Department of Intensive Care (F.S., J.C., J.-L.V.), Erasme University Hospital, Université Libre de Bruxelles, Brussels, Belgium the Department of Anesthesiology and Intensive Care, Hôpitaux Universitaires Paris-Sud, Université Paris-Sud, Université Paris-Saclay, Hôpital De Bicêtre, Assistance Publique Hôpitaux de Paris, Le Kremlin-Bicêtre, France (A.J.) the Department of Anesthesiology, University of California, San Diego, San Diego, California (B.A.) the Department of Anesthesiology and Perioperative Medicine, David Geffen School of Medicine, Los Angeles, California (M.C.) the Department of Anesthesiology and Perioperative Care, University of California, Irvine, Orange, California (J.R.).

Anesthesiology
|January 5, 2019
PubMed
Abstract

Related Concept Videos

Open and closed-loop control systems01:17

Open and closed-loop control systems

Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
1.7K
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
545
One-Compartment Model: IV Infusion01:09

One-Compartment Model: IV Infusion

Intravenous (IV) infusion is often utilized when continuous and controlled drug delivery is necessary, such as during surgery or in the treatment of chronic diseases. This method offers numerous advantages, including immediate drug action, precise control over dosage, and bypassing the first-pass metabolism.
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
509
Titration of a Polyprotic Acid02:08

Titration of a Polyprotic Acid

A polyprotic acid contains more than one ionizable hydrogen and undergoes a stepwise ionization process.  If the acid dissociation constants of the ionizable protons differ sufficiently from each other, then the titration curve for such polyprotic acid generates a distinct equivalence point for each of its ionizable hydrogens. Therefore, titration of a diprotic acid results in the formation of two equivalence points, whereas the titration of a triprotic acid results in the formation of three...
105.1K
Two-Compartment Open Model: IV Infusion01:15

Two-Compartment Open Model: IV Infusion

A two-compartment model is a vital tool in pharmacokinetics, providing an essential understanding of drug behavior, especially for those administered via zero-order intravenous infusion. This model outlines two compartments: the central compartment, where elimination occurs, and the peripheral compartment.
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
593
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of...
141.1K