Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

9.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.3K
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

1.2K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Gain01:15

Gain

410
Gain and phase shift are properties of linear circuits that describe the effect a circuit has on a sinusoidal input voltage or current. The circuit's behavior that contains reactive elements will depend on the frequency of the input sinusoid. As a result, it is observed that the gain and phase shift will all be frequency functions.
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.
410
Automatic Processing and Automatic Social Behavior01:28

Automatic Processing and Automatic Social Behavior

252
Automatic processing refers to the cognitive operations that occur without conscious intent or awareness, playing a fundamental role in shaping social cognition and behavior. These processes enable individuals to navigate complex social environments efficiently by relying on mental shortcuts and pre-existing knowledge structures known as schemas. One of the most influential mechanisms underlying automatic processing is priming, which subtly activates mental representations through exposure to...
252
Nuclear Magnetic Resonance (NMR): Overview01:07

Nuclear Magnetic Resonance (NMR): Overview

6.9K
Nuclear magnetic resonance (NMR) is a phenomenon exhibited by certain nuclei that can absorb characteristic radio frequency radiation under certain conditions. NMR has been extensively applied in molecular spectroscopy and medical diagnostic imaging. In both these applications, the molecule or subject under study is placed in a magnetic field and irradiated with radio frequency energy.
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
6.9K
Resonance02:52

Resonance

65.2K
The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N-O and N=O bonds.
65.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Capillary ratchets activated by interfacial flows for versatile torque generation and microassembly.

Science advances·2026
Same author

IrTMes - a stable SABRE catalyst for the hyperpolarization of [1-<sup>13</sup>C]-pyruvate.

The Analyst·2026
Same author

Variability in moderate-to-vigorous physical activity assessment: Comparing tri-axial accelerometry cut-off points in children.

Sports medicine and health science·2026
Same author

The use of arteriovenous fistula for cancer chemotherapy administration in hemodialysis patients.

The journal of vascular access·2026
Same author

The psychological characteristics behind talented soccer players: a systematic review with meta-analysis.

Frontiers in psychology·2026
Same author

Miniaturization and Optimization of NMR Shimsets Allow Efficient Field Shimming.

Analytical chemistry·2026

Related Experiment Video

Updated: Jan 31, 2026

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
07:42

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Published on: July 20, 2022

3.4K

Automatic Adaptive Gain for Magnetic Resonance Sensitivity Enhancement.

Mazin Jouda1, Erwin Fuhrer1, Pedro Silva1

  • 1Institute of Microstructure Technology (IMT) , Karlsruhe Institute of Technology (KIT) , Karlsruhe , Baden-Württemberg 76131 , Germany.

Analytical Chemistry
|January 5, 2019
PubMed
Summary

This study introduces automatic adaptive gain (AGAIN) to improve magnetic resonance (MR) signal quality. The method enhances signal-to-quantization noise ratio (SQNR) and signal-to-noise ratio (SNR) in MR imaging.

More Related Videos

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
13:56

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism

Published on: November 19, 2014

20.7K
Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
06:24

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model

Published on: April 18, 2015

15.7K

Related Experiment Videos

Last Updated: Jan 31, 2026

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
07:42

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Published on: July 20, 2022

3.4K
The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
13:56

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism

Published on: November 19, 2014

20.7K
Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
06:24

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model

Published on: April 18, 2015

15.7K

Area of Science:

  • Medical Physics
  • Biophysics
  • Spectroscopy

Background:

  • Magnetic resonance (MR) signals naturally decay over acquisition time.
  • This decay leads to a reduced signal-to-quantization noise ratio (SQNR) and signal-to-noise ratio (SNR).
  • Conventional methods fix receiver gain, limiting SNR to early signal points.

Purpose of the Study:

  • To develop and validate a novel method for enhancing SQNR and SNR in MR signal acquisition.
  • To introduce a dynamic gain adjustment technique that compensates for signal decay.
  • To provide a generalizable solution applicable to various MR systems.

Main Methods:

  • Implemented an automatic adaptive gain (AGAIN) method.
  • Dynamically adjusted receiver gain before analog-to-digital conversion (ADC).
  • Utilized a closed-loop system with the MR signal envelope as the control signal and incorporated a gain modulation monitoring mechanism.

Main Results:

  • Achieved an SNR enhancement factor of 2.64 on a custom spectrometer.
  • Observed an SNR enhancement factor of 1.4 on a commercial spectrometer.
  • Demonstrated the method's effectiveness in improving signal quality.

Conclusions:

  • The AGAIN method significantly enhances SNR in magnetic resonance imaging.
  • The technique is robust, generalizable, and requires minimal hardware modification.
  • This approach offers a practical solution for improving MR data quality across different systems.