Related Experiment Video
Updated: Jan 31, 2026

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
Published on: June 3, 2020
Enhanced Quadrupole and Octupole Strength in Doubly Magic ^{132}Sn
D Rosiak1, M Seidlitz1, P Reiter1
1Institut für Kernphysik, Universität zu Köln, Zülpicher Straße 77, D-50937 Köln, Germany.
Abstract:
The first 2^{+} and 3^{-} states of the doubly magic nucleus ^{132}Sn are populated via safe Coulomb excitation employing the recently commissioned HIE-ISOLDE accelerator at CERN in conjunction with the highly efficient MINIBALL array. The ^{132}Sn ions are accelerated to an energy of 5.49 MeV/nucleon and impinged on a ^{206}Pb target. Deexciting γ rays from the low-lying excited states of the target and the projectile are recorded in coincidence with scattered particles. The reduced transition strengths are determined for the transitions 0_{g.s.}^{+}→2_{1}^{+}, 0_{g.s.}^{+}→3_{1}^{-}, and 2_{1}^{+}→3_{1}^{-} in ^{132}Sn. The results on these states provide crucial information on cross-shell configurations which are determined within large-scale shell-model and Monte Carlo shell-model calculations as well as from random-phase approximation and relativistic random-phase approximation. The locally enhanced B(E2;0_{g.s.}^{+}→2_{1}^{+}) strength is consistent with the microscopic description of the structure of the respective states within all theoretical approaches. The presented results of experiment and theory can be considered to be the first direct verification of the sphericity and double magicity of ^{132}Sn.
Related Concept Videos
Magical Thinking
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...

