Related Experiment Video
Updated: Jan 31, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Quantitative measurement of selected protein biomarkers of endothelial dysfunction in plasma by micro-liquid
Joanna Suraj1, Anna Kurpińska2, Magdalena Sternak2
1Jagiellonian University, Jagiellonian Centre for Experimental Therapeutics, Bobrzynskiego 14, 30-348 Krakow, Poland; Jagiellonian University Medical College, Faculty of Pharmacy, Chair and Department of Toxicology, Medyczna 9, 30-688 Krakow, Poland.
Abstract:
The aim of this study was to develop and validate the novel microLC/MS-MRM method for the simultaneous quantification of six proteins: angiopoietin 2 (Angpt-2), soluble form of fms-like tyrosine kinase 1 (sFLT-1), plasminogen activator inhibitor 1 (PAI-1), tissue plasminogen activator (t-PA), endocan (ESM-1), soluble form of E-selectin (sE-sel), and one peptide: adrenomedullin (ADM) in mouse plasma. Two approaches were compared: a stable isotope dilution (SID) method- used as a reference and a modified SID (mSID) procedure. In SID strategy the calibration curves were used, whereas in mSID the ratio between the chromatogram peak area of endogenous tryptic peptides at unknown concentration to chromatogram peak area of exogenous, stable isotope-labelled internal standards (SISs) added to the sample at known concentration was calculated. The microLC/MS-MRM method in the SID approach was linear from 0.250 pmol/mL to 250 pmol/mL for Angpt-2; 5 pmol/mL to 5000 pmol/mL for sFLT-1; 2.5 pmol/mL to 5000 pmol/mL for PAI-1; 0.375 pmol/mL to 250 pmol/mL for t-PA; 0.375 pmol/mL to 187.5 pmol/mL for ESM-1; 2.5 pmol/mL to 5000 pmol/mL for sE-sel and 0.375 pmol/mL to 250 pmol/mL for ADM. LPS-induced changes in plasma assessed based on SID and mSID approaches gave comparable quantitative results and featured LPS-induced dysregulation of endothelial permeability (Angpt-2, sFLT-1), glycocalyx injury (SDC-1) accompanied by a pro-thrombotic response (PAI-1). In addition, we applied microLC/MS-MRM method with mSID strategy to analyze human plasma samples from patients with chronic myeloid leukemia (CML) and obstructive sleep apnoea (OSA) and demonstrated usefulness of the method to characterize endothelial function in humans. In conclusion, the microLC/MS-MRM method with mSID strategy applied for simultaneous quantification of protein biomarkers of endothelial function in plasma represents a novel targeted proteomic platform for the comprehensive evaluation of endothelial function in mice and humans.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
Tandem Mass Spectrometry
Mass Spectrometry: Isotope Effect
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Isotopes
An element's atomic mass, or weight,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences