Related Experiment Video
Updated: Jan 31, 2026

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Dual-channel ITO-microfluidic electrochemical immunosensor for simultaneous detection of two mycotoxins
Lin Lu1, Sundaram Gunasekaran1
1Department of Biological Systems Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA.
Abstract:
Due to the widely occurring co-contamination of mycotoxins in raw food materials, simultaneous monitoring of multiple mycotoxins is needed. Herein, we report the design and fabrication of an electrochemical immunosensor for simultaneous detection of two mycotoxins, fumonisin B1 (FB1) and deoxynivalenol (DON), in a single test. A dual-channel three-electrode electrochemical sensor pattern was etched on a transparent indium tin oxide (ITO)-coated glass via photolithography and was integrated with capillary-driven polydimethylsiloxane (PDMS) microfluidic channel. The two working electrodes were functionalized with gold nanoparticles and anti-FB1 and anti-DON antibodies. Tests were performed by incubating the working electrodes in a sample solution introduced in the PDMS channel. The formation of toxin-antibody immunocomplexes on the working electrode surface produced electrochemical signal responses, which were recorded and compared with control signal to quantify individual mycotoxin concentrations. Using this dual-channel ITO-microfluidic electrochemical immunosensor we achieved limits of detection (LODs) of 97 pg/mL and 35 pg/mL, respectively for FB1 and DON, and their corresponding linear ranges of detection were 0.3-140 ppb and 0.2-60 ppb. The sensor performance, which remained stable for two weeks under proper storage, was validated by testing with ground corn extract used as a real food matrix.
Related Concept Videos
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Interfacial Electrochemical Methods: Overview
Channel Rhodopsins
Rhodopsins belong to the family of cell surface proteins called G-protein coupled receptors,...
Non-gated Ion Channels
Compared to the gated ion channels, the non-gated channels, also known as leakage or passive channels, have no gating mechanism....