Related Experiment Video
Updated: Jan 31, 2026

Assembly and Characterization of Polyelectrolyte Complex Micelles
Published on: March 2, 2020
Electrochemical biosensor based on polyelectrolyte complexes for the determination of reversible inhibitors of
Alexey Ivanov1, Regina Davletshina1, Indira Sharafieva1
1A.M. Butlerov' Chemistry Institute of Kazan Federal University, 18 Kremlevskaya street, Kazan 420008, Russian Federation.
Abstract:
Reversible inhibitors of acetylcholinesterase are increasingly applied in the Alzheimer's disease therapy. Their determination with biosensors requires special attention to the enzyme immobilization due to importance of electrostatic and steric factors affecting accessibility of the active site to the substrate and inhibitor present simultaneously. In this work, polyelectrolyte complexes have been assembled from electrochemically inactive components with implementation of acetylcholinesterase from electric eel. The influence of the complex components and enzyme position on the assembling efficiency was explored using surface plasmon resonance and kinetic parameters of the enzyme with amperometry with Co phtalocyanine mediator. The biosensor developed showed robust response toward donepezil and berberine with limit of detection of 0.46 and 70 nM, respectively, within 1 min after inhibitor addition. The sensitivity of determination coincides or is better than characteristics of biosensors based on covalently attached AChE described in the literature. The biosensor was tested on the example of drug determination in spiked samples of artificial urine (recovery 103% for 0.6 nM donepezil and 110% for 0.1 μM berberine).
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Eukaryotic Transcription Inhibitors
Eukaryotic transcription inhibitors usually contain two distinct domains, a...
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Formation of Complex Ions
Reversible and Irreversible Processes
Diode: Reverse bias