Background:
The next-generation convex probe endobronchial ultrasound (CP-EBUS) was developed to improve the ease of operation and the acquisition of EBUS skills for new trainees. The aim of this study was to evaluate the changes in the prototype next-generation CP-EBUS compared with the current CP-EBUS.
Methods:
The prototype next-generation CP-EBUS, with a decreased forward oblique view, more flexible angulation range, smaller ultrasound probe, and sharper needle angle, was compared with the current CP-EBUS. The operability, which was evaluated by using a 5-level Likert-type scale, and safety were evaluated in 2 live pigs, a cadaveric lung, and 10 ex vivo human lungs by 9 bronchoscopists. The time required to access the upper lobe bronchus and the time required to detect prespecified lymph node stations by 7 novice bronchoscopists with both CP-EBUS were compared with assess the operability difference for new trainees.
Results:
In all evaluated models, operability (eg, maneuverability, endoscopic visibility, bronchial trees selectivity, insertability to the upper airway) was scored 5 (significantly improved). All trainee bronchoscopists were able to access the upper lobe bronchi and detect each lymph node except 4R significantly faster than with the current CP-EBUS without any airway damage.
Conclusions:
The next-generation CP-EBUS has improved operability, which resulted in better access to each lobar bronchus and more prompt detection of mediastinal or hilar lymph nodes. These improvements may allow more precise lymph node staging and diagnosis, as well as improve EBUS procedural skill acquisition, once introduced to clinical practice.
Related Concept Videos
Self-Evaluation Maintenance Model
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Preclinical Development: Overview
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Self-Evaluation: Self-Enhancement and Self-Verification
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: