Near-source air quality impact of a distributed natural gas combined heat and power facility
Bo Yang1, Jiajun Gu1, Tong Zhang1
1Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA.
Abstract:
The wide adoption of combined heat and power (CHP) can not only improve energy efficiency, but also strengthens energy system resiliency. While CHP reduces overall emissions compared to generating the same amount of electricity and heat separately, its on-site nature also means that CHP facilities operate in populated areas, raising concerns over their near-source air quality impact. Evaluation of the near-source impact of distributed CHP is limited by emission data availability, especially in terms of particulate matter (PM). In this paper, we report on stack emission testing results of a community-scale CHP plant with two natural gas turbine units (15 MW each) from measurements conducted in both 2010 and 2015, and assess the near-source air quality impact using an integrated modeling framework using the stack test results, site-specific meteorological data and terrain profiles with buildings. The NOx removal efficiency by selective catalytic reduction (SCR) is estimated to be ∼83% according to the emission testing. The integrated framework employs AERMOD to screen air quality in a 2.7 km × 2.3 km domain from 2011 to 2015 to identify the highest ground-level concentrations (GLCs). Examining the corresponding meteorological conditions, we find that those high GLCs appeared during the stable atmospheric boundary layer with relative high wind speed. Next, the worse-case scenarios identified from the screening process are simulated using the detailed Unsteady Reynolds Averaged Navier-Stokes (URANS) model coupled with a chemistry solver. The results generally show low GLCs of primary PM2.5 for this case study. However, our analysis also suggests greater building downwash impacts with the presence of taller and denser urban structures. Therefore, the near-source impact of natural gas-fired CHP in large metropolitan areas is worthy of further investigation.
More Related Videos
05:34Operating and Biocontainment Procedures of a Facility for Laboratory Mice with a Natural Microbiome: Immunophenotyping Procedure
Published on: December 13, 2024
05:21Evaluation of the Impact of a New Cooling Cell Processor System on Islet Cell Isolation Facility
Published on: August 11, 2023
Related Concept Videos
Power System Distribution
The transmission system is designed...
Heat Capacities of an Ideal Gas I
Molar heat capacity quantifies the ratio of the amount of heat added (or removed) to increase (or decrease) the...
Heat Capacities of an Ideal Gas II
Heat Capacities of an Ideal Gas III
Power Distribution in Three-phase and Single Phase Circuits
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...