Neuroprotective activity of leukemia inhibitory factor is relayed through myeloid zinc finger-1 in a rat model of

Stephanie M Davis1, Lisa A Collier1, Elspeth A Foran2

  • 1Department of Neurology, University of Kentucky, 741 S. Limestone BBSRB Room B457, Lexington, KY, 40536-0509, USA.

Metabolic Brain Disease
|January 7, 2019
PubMed

Related Concept Videos

Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
612
Factors Affecting Activity Coefficient01:17

Factors Affecting Activity Coefficient

The extended Debye-Hückel equation indicates that the activity coefficient of an ion in an aqueous solution at 25°C depends on three partially interdependent properties: the ionic strength of the solution, the charge of the ion, and the ion size. 
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
1.6K
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
535
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
767
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
452
Eukaryotic Transcription Activators02:42

Eukaryotic Transcription Activators

Transcription activators are proteins that promote the transcription of genes from DNA to RNA. In most cases, these proteins contain two separate domains ‒ a domain that binds to DNA and a domain for activating transcription; however, in some cases, a single domain is responsible for both binding and activation of transcription, as seen in the glucocorticoid receptor and MyoD.
The binding domains are capable of recognizing and interacting with regulatory sequences on the DNA. These...
12.8K